Comparing the mechanical characteristics between leg lengthening using only an Ilizarov external fixator and leg lengthening over a nail using an external fixator manufactured in Vietnam
- 23 September 2023
- journal article
- research article
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 34 (2) , 839-846
Abstract
Purpose The mechanical characteristics of leg lengthening over a nail (LON) using an external fixator are not well known; specifically, the number of rings and K-wires required for this method has not been determined. This study aimed to compare the mechanical characteristics of leg LON using the simplest configuration for a domestic frame and those of leg lengthening using the Ilizarov frame alone. Methods The mechanical characteristics of cow tibial samples for lengthening over an intramedullary nail in combination with a domestic external fixator (LON samples) and for lengthening with the Ilizarov frame (Ilizarov samples) were evaluated by assessing axial compression, bending load, and torsional load. The research indices were compression stiffness, bending stiffness, torsion stiffness, yield axial load, ultimate axial load, yield bending load, and ultimate bending load. Results No statistically significant differences were observed in the compression stiffness, ultimate axial load, bending stiffness, and ultimate, yield bending forces between the Ilizarov samples and LON samples. The compressive stiffness, yield axial load, and ultimate axial load of the LON samples were 98 ± 1.31 N/mm, 915 ± 23.89 N, and 1032 ± 29.86 N, respectively. The anterior–posterior bending stiffness and lateral bending stiffness of the LON samples were 122.48 ± 2.92 N/mm and 116.34 ± 3.95 N/mm, respectively. The yield anterior–posterior bending and ultimate anterior–posterior bending forces of the LON samples were 616.4 ± 3.64 N and 753.2 ± 3.49 N, respectively. The yield lateral bending and ultimate lateral bending forces of the LON samples were 624.6 ± 4.04 N and 759.0 ± 3.39 N, respectively. The axial torsional stiffness of the LON samples was 1.73 ± 0.05 N m/°, which was significantly lower than that of the Ilizarov samples (2.63 ± 0.03 N m/°). Conclusion No statistically significant differences were observed in the mechanical fixation characteristics of axial compression and bending between the Ilizarov samples and LON samples. However, the axial torsional stiffness of the Ilizarov samples was statistically greater than that of the LON samples. We recommend using the simplest configuration for domestic frames in combination with LON for limb lengthening. Partial weight-bearing is permitted in the distraction stage. Level of evidence Case–control study.Keywords
This publication has 19 references indexed in Scilit:
- Tibial lengthening over an intramedullary nail in patients with short stature or leg-length discrepancy: a comparative studyInternational Orthopaedics, 2011
- Tibial Lengthening Over an Intramedullary NailTechniques in Orthopaedics, 2009
- Lower limb lengthening: is there a difference in the lengthening index and infection rates of lengthening with external fixators, external fixators with intramedullary nails or intramedullary nailing alone? A systematic review of the literatureEuropean Journal of Orthopaedic Surgery & Traumatology, 2009
- Tibial lengthening using a reamed type intramedullary nail and an Ilizarov external fixatorInternational Orthopaedics, 2008
- Limb lengthening over a nail can safely reduce the duration of external fixationIndian Journal of Orthopaedics, 2008
- Biomechanical advantage of lengthening of the femur with an external fixator over an intramedullary nailJournal of Pediatric Orthopaedics B, 2007
- Cosmetic bilateral leg lengtheningThe Journal of Bone and Joint Surgery. British volume, 2005
- Tibial lengthening over an intramedullary nailJournal of Orthopaedic Science, 2005
- Rapid application fracture fixators – an evaluation of mechanical performanceClinical Biomechanics, 2001
- Tibial Lengthening Over Nails (LON)Techniques in Orthopaedics, 1997