Quantification of Lipid Mediator Metabolites in Human Urine from Asthma Patients by Electrospray Ionization Mass Spectrometry: Controlling Matrix Effects
Authors:
- David BalgomaDBDavid Balgoma
- Joshua RokachJRJoshua Rokach
- Sven-Erik DahlénSDSven-Erik Dahlén
- Craig E. WheelockCWCraig E. Wheelock
- 17 July 2013
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 85 (16) , 7866-7874
Abstract
Eicosanoids (e.g., prostaglandins and leukotrienes) are inflammatory signaling molecules that are metabolized and excreted in urine. The quantification of eicosanoid metabolites in human urine has been demonstrated to provide insight into the inflammatory and oxidative stress status of the individual. However, urine is a complex matrix that can exhibit profound matrix effects for quantification via liquid chromatography coupled to mass spectrometry (LC-MS/MS). This phenomenon can lead to impairment and biasing of results, because the sample background is dependent on the fluid intake and water–salt balance. Herein we describe an analytical methodology to address these limitations via the normalization of extracted urine volume by the ratio of absorbance at 300 nm to an optimized reference material. The platform is composed of 4 LC-MS/MS methods that collectively quantify 26 lipid mediators and their metabolites, with on-column limits of detection between 0.55 and 15 fmol. Prior to optimization, internal standards exhibited strong matrix effects with up to 50% loss of signal. Notably, the accuracy of exact deuterated structural analogues was found to vary based upon the number of incorporated deteurium. The platform was used to analyze urine from 16 atopic asthmatics under allergen provocation, showing increases in metabolites of prostaglandin D2, cysteinyl leukotrienes, and isoprostanes following the challenge. This method presents a functional and reproducible approach to addressing urine-specific matrix effects that can be readily formatted for quantifying large numbers of samples.Keywords
This publication has 50 references indexed in Scilit:
- Application of ’omics technologies to biomarker discovery in inflammatory lung diseasesEuropean Respiratory Journal, 2013
- Annotation of the Human Adult Urinary Metabolome and Metabolite Identification Using Ultra High Performance Liquid Chromatography Coupled to a Linear Quadrupole Ion Trap-Orbitrap Mass SpectrometerAnalytical Chemistry, 2012
- A simple and robust UPLC-SRM/MS method to quantify urinary eicosanoidsJournal of Lipid Research, 2012
- A ultra‐pressure liquid chromatography/triple quadrupole tandem mass spectrometry method for the analysis of 13 eicosanoids in human urine and quantitative 24 hour values in healthy volunteers in a controlled constant dietRapid Communications in Mass Spectrometry, 2012
- Recent and potential developments in the analysis of urine: A reviewAnalytica Chimica Acta, 2011
- Quantitative Profiling Method for Oxylipin Metabolome by Liquid Chromatography Electrospray Ionization Tandem Mass SpectrometryAnalytical Chemistry, 2009
- Eoxins are proinflammatory arachidonic acid metabolites produced via the 15-lipoxygenase-1 pathway in human eosinophils and mast cellsProceedings of the National Academy of Sciences, 2008
- Synthesis and metabolism of leukotrienes in γ-glutamyl transpeptidase deficiencyJournal of Lipid Research, 2004
- Analyses of prostaglandin D2 metabolites in urine: comparison between enzyme immunoassay and negative ion chemical ionisation gas chromatography-mass spectrometryProstaglandins & Other Lipid Mediators, 1999
- Metabolism of 8‐iso‐prostaglandin F2αFEBS Letters, 1998