New Techniques for Fault Detection Analysis by Injecting Additional Frequency Test
- 1 April 2006
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 2087-2090
Abstract
Double frequency tests are used for evaluating stator windings analyzing the temperature. Likewise, signal injection on induction machines is used on sensorless motor control fields to find out the rotor position. Motor current signature analysis (MCSA) is the most widely used method for identifying faults in induction motors. MCSA focuses its efforts on the spectral analysis of stator current. Motor faults such as broken rotor bars, bearing damage and eccentricity of the rotor axis can be detected. However, the method presents some problems at low speed and low torque, mainly due to the proximity between the frequencies to be detected and the small amplitude of the resulting harmonics. This paper proposes to inject an additional voltage into the machine under test at a frequency different from the fundamental one, and then to study the resulting harmonics around the new frequencies appearing due to the composition between injected and main frequenciesKeywords
This publication has 6 references indexed in Scilit:
- Induction Machine Fault Diagnostic Analysis With Wavelet TechniqueIEEE Transactions on Industrial Electronics, 2004
- Statistical analysis on a case study of load effect on PSD technique for induction motor broken rotor bar fault detection2003
- Case histories of current signature analysis to detect faults in induction motor drives2003
- A review of induction motors signature analysis as a medium for faults detectionIEEE Transactions on Industrial Electronics, 2000
- Vibration and current monitoring for detecting airgap eccentricity in large induction motorsIEE Proceedings B Electric Power Applications, 1986
- Der Stabbruch im Käfiǵläufer eines AsynchronmotorsElectrical Engineering, 1984