Enhanced Ionic Polymer–Metal Composites with Nanocomposite Electrodes for Restoring Eyelid Movement of Patients with Ptosis
Open Access
- 24 January 2023
- journal article
- research article
- Published by MDPI AG in Nanomaterials
- Vol. 13 (3) , 473
Abstract
The present study aims to use enhanced ionic polymer–metal composites (IPMC) as an artificial muscle (a soft-active actuator) to restore eyelid movement of patients with ptosis. The previous eyelid movement mechanisms contained drawbacks, specifically in the lower eyelid. We used finite element analysis (FEA) to find the optimal mechanism among two different models (A and B). In addition to common electrodes of IPMC (gold and platinum), the bovine serum albumin (BSA) and microcrystalline cellulose (MCC) polymers, with optimal weight percentages of carbon nanotube (CNT) nanofiller, were also utilized as non-metallic electrodes to improve the efficiency of the IPMC actuator. In both models, IPMC with nanocomposite electrodes had higher efficiency as compared to the metallic electrodes. In model A, which moved eyelids indirectly, IPMC with MCC-CNT electrode generated a higher force (25.4%) and less stress (5.9 times) as compared to IPMC with BSA-CNT electrode. However, the use of model A (even with IPMCs) with nanocomposite electrodes can have limitations such as possible malposition issues in the eyelids (especially lower). IPMC with MCC-CNT nanocomposite electrode under model B, which moved eyelids directly, was the most efficient option to restore eyelid movement. It led to higher displacements and lower mechanical stress damage as compared to the BSA-CNT. This finding may provide surgeons with valuable data to open a window in the treatment of patients with ptosis.Keywords
Funding Information
- Margaret Hackett Family Program (MHFP)
This publication has 61 references indexed in Scilit:
- Effective permittivity of periodic composite materials: Numerical modeling by the finite element methodJournal of Electrostatics, 2012
- A Closed‐Loop Stimulation System Supplemented with Motoneurone Dynamic Sensitivity Replicates Natural Eye BlinksOtolaryngology–Head and Neck Surgery, 2011
- Chiari Type I MalformationThe Neurologist, 2011
- A helical ionic polymer–metal composite actuator for radius control of biomedical active stentsSmart Materials and Structures, 2011
- Soft Robotics: Challenges and PerspectivesProcedia Computer Science, 2011
- Acute respiratory arrest following partial suboccipital cranioplasty for cerebellar ptosis from Chiari malformation decompressionNeurosurgical Focus, 2008
- Ionic polymer–conductor composites as biomimetic sensors, robotic actuators and artificial muscles—a reviewElectrochimica Acta, 2003
- Ionic polymer metal composites: II. Manufacturing techniquesSmart Materials and Structures, 2003
- The Poisson's ratio of microcrystalline celluloseInternational Journal of Pharmaceutics, 1994
- The Young's modulus of pharmaceutical materialsInternational Journal of Pharmaceutics, 1987