A Non-Enzymatic Biosensor Based on Pd Decorated Reduced Graphene Oxide Poly (2-anilinoethanol) Nanocomposite and Its Application for the Determination of Dopamine
- 8 February 2018
- journal article
- research article
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 165 (3) , B150-B159
Abstract
A new electrocatalyst based on Pd decorated reduced graphene oxide poly (2-anilinoethanol) nanocomposite (RGO-P2AE-Pd) was synthesized and characterized by scanning electron microscopy (SEM), the transmission electron microscopy (TEM) and FT-IR spectroscopy, and cyclic voltammetry (CV). The SEM and SEM images displayed that the Pd nanoparticles of an average size of 25 nm were immobilized on the RGO-P2AE nanocomposite. The prepared electrocatalyst which was casted on the surface of a glassy carbon electrode (GCE), was used as a non-enzymatic biosensor for detecting dopamine (DA). To determine DA, RGO-P2AE-Pd electrocatalytic activity was studied using cyclic voltammetry and differential pulse voltammetry. The developed sensor represented a linear range up to 0.25 mM of DA, which is quite more than most of the available non-enzymatic DA sensors based on nanocomposites. The detection limit was found to be 2.4 × 10−8 M (at signal/noise = 3). In addition, the biosensor showed an excellent reproducibility, stability and selectivity properties. These excellent performances make RGO-P2AE-Pd a good non-enzymatic DA sensor in pharmaceutical and clinical samples despite the presence of interfering agents such as ascorbic acid (AA) and uric acid (UA).Keywords
This publication has 56 references indexed in Scilit:
- Ultrasonication-assisted ultrafast reduction of graphene oxide by zinc powder at room temperatureCarbon, 2011
- Electrochemical sensing based on graphene oxide/Prussian blue hybrid film modified electrodeElectrochimica Acta, 2011
- Development of a biomimetic chitosan film-coated gold electrode for determination of dopamine in the presence of ascorbic acid and uric acidElectrochimica Acta, 2010
- Highly Sensitive and Selective Dopamine Biosensor Fabricated with Silanized GrapheneThe Journal of Physical Chemistry C, 2010
- A novel label-free electrochemical aptasensor for thrombin based on the {nano-Au/thionine}n multilayer films as redox probesAnalytica Chimica Acta, 2010
- Promoting effect of electroactive polymer supports on the catalytic performances of palladium-based catalysts for nitrite reduction in waterApplied Catalysis B: Environment and Energy, 2007
- Modification of palladium-based catalysts by chalcogenes for direct methanol fuel cellsElectrochemistry Communications, 2007
- Oxygen kinetics and mechanism at electrocatalysts on the base of palladium–iron systemElectrochimica Acta, 2007
- Simultaneous voltammetric determination of dopamine and serotonin on carbon paste electrodes modified with iron(II) phthalocyanine complexesAnalytica Chimica Acta, 2001
- Spectroscopic studies of polyaniline protonation with poly(alkylene phosphates)Polymer, 1996