Digital timing: sampling frequency, anti-aliasing filter and signal interpolation filter dependence on timing resolution
Authors:
- Sanghee ChoSCSanghee Cho
- Ron GraziosoRGRon Grazioso
- Nan ZhangNZNan Zhang
- Mehmet AykacMAMehmet Aykac
- Matthias SchmandMSMatthias Schmand
- 15 November 2011
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (23) , 7569-7583
Abstract
The main focus of our study is to investigate how the performance of digital timing methods is affected by sampling rate, anti-aliasing and signal interpolation filters. We used the Nyquist sampling theorem to address some basic questions such as what will be the minimum sampling frequencies? How accurate will the signal interpolation be? How do we validate the timing measurements? The preferred sampling rate would be as low as possible, considering the high cost and power consumption of high-speed analog-to-digital converters. However, when the sampling rate is too low, due to the aliasing effect, some artifacts are produced in the timing resolution estimations; the shape of the timing profile is distorted and the FWHM values of the profile fluctuate as the source location changes. Anti-aliasing filters are required in this case to avoid the artifacts, but the timing is degraded as a result. When the sampling rate is marginally over the Nyquist rate, a proper signal interpolation is important. A sharp roll-off (higher order) filter is required to separate the baseband signal from its replicates to avoid the aliasing, but in return the computation will be higher. We demonstrated the analysis through a digital timing study using fast LSO scintillation crystals as used in time-of-flight PET scanners. From the study, we observed that there is no significant timing resolution degradation down to 1.3 Ghz sampling frequency, and the computation requirement for the signal interpolation is reasonably low. A so-called sliding test is proposed as a validation tool checking constant timing resolution behavior of a given timing pick-off method regardless of the source location change. Lastly, the performance comparison for several digital timing methods is also shown.Keywords
This publication has 26 references indexed in Scilit:
- Timing performance comparison of digital methods in positron emission tomographyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2010
- Design of an FPGA-Based Algorithm for Real-Time Solutions of Statistics-Based PositioningIEEE Transactions on Nuclear Science, 2010
- Real-Time Digital Timing in Positron Emission TomographyIEEE Transactions on Nuclear Science, 2008
- Timing Improvement by Low-Pass Filtering and Linear Interpolation for the LabPET ScannerIEEE Transactions on Nuclear Science, 2008
- Time resolution studies using digital constant fraction discriminationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2007
- A Weighted Least Mean Squares Linear Algorithm for Energy and Occurrence Time Measurement of PulseIEEE Transactions on Nuclear Science, 2007
- Sampling Pulses for Optimal TimingIEEE Transactions on Nuclear Science, 2007
- Real time digital signal processing implementation for an APD-based PET scanner with phoswich detectorsIEEE Transactions on Nuclear Science, 2006
- First experimental results of time-of-flight reconstruction on an LSO PET scannerPhysics in Medicine & Biology, 2005
- Walk correction for scintillation countersNuclear Instruments and Methods, 1970