Measurement of eNO with portable analyser might improve the management of persistent cough at primary care practice in Japan
- 26 November 2014
- journal article
- Published by Wiley in The Clinical Respiratory Journal
- Vol. 10 (3) , 380-388
Abstract
Background and Aims: There are some controversial reports that investigated the usefulness of exhaled nitric oxide (eNO) to predict the efficacy of inhaled corticosteroids (ICS) in chronic cough patients. Therefore, we retrospectively analysed the usefulness of eNO measurement with portable analyser to predict the requirement of ICS therapy in persistent cough (defined as lasting for 3 weeks or more) patients in Japan and investigated whether it might improve the management of persistent cough at primary care practice.Methods: We retrospectively reviewed the clinical records of adult patients who had been referred to our hospital for persistent cough from 1 June 2009 to 30 April 2011.Results: Forty‐two patients had the requirement of ICS (group S) and 35 patients had no requirement of ICS (group N). Forty‐three per cent of the patients who required ICS had not received ICS, and 29% of the patients who did not required ICS had received ICS. In the steroid‐naive patients without current smoking, mean eNO level was significantly higher in group S [60.6 ± 14.1 perts per billion (ppb) vs 22.2 ± 2.3 ppb, P = 0.001] and the sensitivity and the specificity of eNO for predicting the requirement of ICS were 78.6% and 80.0%, respectively. The rate of the patients who received inappropriate treatment about ICS tended to be reduced from 41% to 21% if the eNO was used to predict the requirement of ICS with cut‐off value of eNO 26.5 ppb (P = 0.118).Conclusion: Measurement of eNO could be one of the management tools for persistent cough at primary care practice.Keywords
This publication has 33 references indexed in Scilit:
- Exhaled nitric oxide levels in patients with atopic cough and cough variant asthmaRespirology, 2008
- Use of Exhaled Nitric Oxide in Predicting Response to Inhaled Corticosteroids for Chronic CoughMayo Clinic Proceedings, 2007
- Reliability of a new hand‐held device for the measurement of exhaled nitric oxideAllergy, 2007
- Exhaled Nitric Oxide in a Population Sample of AdultsRespiration, 2007
- Importance of atopic cough, cough variant asthma and sinobronchial syndrome as causes of chronic cough in the Hokuriku area of JapanRespirology, 2005
- Reduced pH and chloride levels in exhaled breath condensate of patients with chronic coughThorax, 2004
- Effect of inhaled corticosteroids on symptom severity and sputum mediator levels in chronic persistent coughJournal of Allergy and Clinical Immunology, 2004
- A comparison of exhaled nitric oxide and induced sputum as markers of airway inflammationJournal of Allergy and Clinical Immunology, 2000
- Effect of inhaled steroids on airway hyperresponsiveness, sputum eosinophils, and exhaled nitric oxide levels in patients with asthmaThorax, 1999
- Single-breath nitric oxide measurements in asthmatic patients and smokersThe Lancet, 1994