The tolerance of anisometropia
- 26 November 2019
- journal article
- research article
- Published by Wiley in Acta Ophthalmologica
- Vol. 98 (4) , 418-426
Abstract
Purpose: This study examines aniseikonia, Aniseikonia tolerance range (ATR), anisometropia and patient‐reported outcomes (PRO) in an anisometropic population compared with a non‐anisometropic population. The relationship between anisometropia and aniseikonia is determined, and the correlations between aniseikonia, anisometropia and ATR versus PRO are described.Methods: One hundred and twenty‐three patients with IOL‐induced anisometropia ≥1 dioptre (D) (the anisometropic group) and 17 patients who had IOL‐induced anisometropia 1 and 3 D. There was no difference in PRO between the control group and the anisometropic group (Mann–Whitney, p‐values VFQ: 0.96, CISS: 0.06). There was no correlation between anisometropia and PRO (Spearman's rank correlation test p‐values: VFQ: 0.54, CISS: 0.57). Patients with low ATR were more sensitive towards anisometropia and had lower PRO than patients with high ATR (Mann–Whitney, p‐values: VFQ: 0.0008, CISS: 0.11). A large tolerance of aniseikonia was observed.Conclusion: No correlation between PRO and anisometropia or aniseikonia was found. Patients with low ATR are at risk of visual complaints if they are exposed to IOL‐induced anisometropia. ATR might be a future screening tool in cataract patients.Keywords
This publication has 32 references indexed in Scilit:
- Visual function and patient satisfaction: Comparison between bilateral diffractive multifocal intraocular lenses and monovision pseudophakiaJournal of Cataract & Refractive Surgery, 2011
- Vision-Related Quality of Life and Visual Function after Vitrectomy for Various Vitreoretinal DisordersInvestigative Ophthalmology & Visual Science, 2010
- Does spatial invariance result from insensitivity to change?Journal of Vision, 2007
- Human Adult Cortical Reorganization and Consequent Visual DistortionThe Journal of Neuroscience, 2007
- Validity and reliability of the revised convergence insufficiency symptom survey in adultsOphthalmic and Physiological Optics, 2004
- Validity and Reliability of the Revised Convergence Insufficiency Symptom Survey in Children Aged 9 to 18 YearsOptometry and Vision Science, 2003
- Stereopsis, stereotests, and their relation to vision screening and clinical practiceClinical and Experimental Optometry, 1997
- The influence of aniseikonia on the VEP by random‐dot stereogramActa Ophthalmologica, 1989
- ANISEIKONIA AND REFRACTIVE PROBLEMSInternational Ophthalmology Clinics, 1965
- Aniseikonia—A Clinical Report Covering a Ten Year PeriodClinical and Experimental Optometry, 1944