Transcatheter closure of large ostium secundum atrial septal defects in symptomatic small children: A single-center retrospective study
Open Access
- 1 November 2023
- journal article
- research article
- Published by Medknow in Annals of Pediatric Cardiology
- Vol. 16 (6) , 393-398
Abstract
Background: In general, the risks associated with transcatheter atrial septal defect (ASD) device closure are reported to be relatively low, but the evidence stems from trials involving adults and older children. Current guidelines do not recommend ASD device closure in children with defect sizes >20 mm due to limited data available in this group of patients. This retrospective study sought to determine the clinical and procedural characteristics of successful transcatheter ASD device closure in small children with large defects and assess the complication rates and reasons for unsuccessful device closure. Methods: We retrospectively reviewed the data of all patients who underwent elective transcatheter closure of ostium secundum ASD in our department between September 2013 and February 2022. All children weighing <20 kg, requiring a device of size 20 mm or greater, were included. Major and minor complications were predefined and indications for referral were evaluated. Echocardiogram reports were reviewed from the time of referral, postcatheterization day 1, and at 1-year follow-up. Results: We identified 40 patients meeting inclusion criteria with a median (interquartile range [IQR]) procedural age of 5 (4–7) years and median (IQR) weight of 14 (12–18) kg. Successful device closure was achieved in 39 patients with a success rate of 97.5%. The total complication rate was 2.5% (95% confidence interval: 0.44%– I2.8%) with only 1 major complication. All children had right heart enlargement and exertional dyspnea, 30% of patients had recurrent lower respiratory tract infections, and 10% had failure to thrive. At 1-year follow-up, a transthoracic echocardiogram showed a well-endothelialized device in a stable position in all the patients, and none of the patients had a residual shunt. Conclusion: In experienced centers, percutaneous ASD closure of large defects in symptomatic small children can be done effectively and safely with a great degree of predictability and a low complication rate.Keywords
This publication has 21 references indexed in Scilit:
- Guidelines for the Echocardiographic Assessment of Atrial Septal Defect and Patent Foramen Ovale: From the American Society of Echocardiography and Society for Cardiac Angiography and InterventionsJournal of the American Society of Echocardiography, 2015
- Techniques and outcomes of transcatheter closure of complex atrial septal defects – Single center experienceIndian Heart Journal, 2014
- Intermediate-Term Effects of Transcatheter Secundum Atrial Septal Defect Closure on Cardiac Remodeling in Children and AdultsPediatric Cardiology, 2010
- Device closure of large atrial septal defects requiring devices ≥20 mm in small children weighing <20 kgCatheterization and Cardiovascular Interventions, 2008
- Device closure of atrial septal defects with the Amplatzer septal occluder: Safety and outcome in infantsThe Journal of Thoracic and Cardiovascular Surgery, 2007
- Transcatheter closure of secundum atrial defect in small childrenCatheterization and Cardiovascular Interventions, 2006
- Time-course of cardiac remodeling following transcatheter closure of atrial septal defectInternational Journal of Cardiology, 2006
- New technique for device closure of large atrial septal defectsCatheterization and Cardiovascular Interventions, 2004
- Outcomes and alternative techniques for device closure of the large secundum atrial septal defectCatheterization and Cardiovascular Interventions, 2003
- Transcatheter closure of very large (≥ 25 mm) atrial septal defects using the Amplatzer septal occluderCatheterization and Cardiovascular Interventions, 2003