Application of the compressed sensing technique to self‐gated cardiac cine sequences in small animals
Open Access
- 16 September 2013
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 72 (2) , 369-380
Abstract
Purpose: Self‐gated cine sequences are a common choice for cardiac MRI in preclinical applications. The aims of our work were to apply the compressed sensing technique to IntraGateFLASH cardiac MRI studies on rats and to find the maximum acceleration factor achievable with this technique.Theory and Methods: Our reconstruction method extended the Split Bregman formulation to minimize the total variation in both space and time. In addition, we analyzed the influence of the undersampling pattern on the acceleration factor achievable.Results: Our results show that acceleration factors of up to 15 are achievable with our technique when appropriate undersampling patterns are used. The introduction of a time‐varying random sampling clearly improved the efficiency of the undersampling schemes. In terms of computational efficiency, the proposed reconstruction method has been shown to be competitive as compared with the fastest methods found in the literature.Conclusion: We successfully applied our compressed sensing technique to self‐gated cardiac cine acquisition in small animals, obtaining an acceleration factor of up to 15 with almost unnoticeable image degradation. Magn Reson Med 72:369–380, 2014.Keywords
Funding Information
- Spanish Ministry of Economy and Competitiveness projects (RECAVA RD07/0014/2009)
- CDTI-CENIT program (RD12/0042/0057, AMIT CEN-20101014)
This publication has 36 references indexed in Scilit:
- Highly accelerated cardiac functional MRI in rodent hearts using compressed sensing and parallel imaging at 9.4TJournal of Cardiovascular Magnetic Resonance, 2012
- Accelerating cine‐MR imaging in mouse hearts using compressed sensingJournal of Magnetic Resonance Imaging, 2011
- Compressed‐sensing motion compensation (CosMo): A joint prospective–retrospective respiratory navigator for coronary MRIMagnetic Resonance in Medicine, 2011
- k‐t group sparse: A method for accelerating dynamic MRIMagnetic Resonance in Medicine, 2011
- A computationally efficient OMP-based compressed sensing reconstruction for dynamic MRIPhysics in Medicine & Biology, 2011
- Evaluation of infarcted murine heart function: comparison of prospectively triggered with self‐gated MRINMR in Biomedicine, 2010
- Combination of compressed sensing and parallel imaging for highly accelerated first‐pass cardiac perfusion MRIMagnetic Resonance in Medicine, 2010
- Patient-adapted reconstruction and acquisition dynamic imaging method (PARADIGM) for MRIInverse Problems, 2008
- Principal strain changes precede ventricular wall thinning during transition to heart failure in a mouse model of dilated cardiomyopathyAmerican Journal of Physiology-Heart and Circulatory Physiology, 2008
- Sparse MRI: The application of compressed sensing for rapid MR imagingMagnetic Resonance in Medicine, 2007