Combined leadless pacemaker and subcutaneous implantable defibrillator therapy: feasibility, safety, and performance
- 3 March 2016
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 18 (11) , 1740-1747
Abstract
Aims The subcutaneous implantable cardioverter-defibrillator (S-ICD) and leadless pacemaker (LP) are evolving technologies that do not require intracardiac leads. However, interactions between these two devices are unexplored. We investigated the feasibility, safety, and performance of combined LP and S-ICD therapy, considering (i) simultaneous device-programmer communication, (ii) S-ICD rhythm discrimination during LP communication and pacing, and (iii) post-shock LP performance. Methods and results The study consists of two parts. Animal experiments: Two sheep were implanted with both an S-ICD and LP (Nanostim, SJM), and the objectives above were tested. Human experience: Follow-up of one S-ICD patient with bilateral subclavian occlusion who received an LP and two LP (all Nanostim, SJM) patients (without S-ICD) who received electrical cardioversion (ECV) are presented. Animal experiments : Simultaneous device-programmer communication was successful, but LP-programmer communication telemetry was temporarily lost (2 ± 2 s) during ventricular fibrillation (VF) induction and 4/54 shocks. Leadless pacemaker communication and pacing did not interfere with S-ICD rhythm discrimination. Additionally, all VF episodes (n = 12/12), including during simultaneous LP pacing, were detected and treated by the S-ICD. Post-shock LP performance was unaltered, and no post-shock device resets or dislodgements were observed (24 S-ICD and 30 external shocks). Human experience : The S-ICD/LP patient showed adequate S-ICD sensing during intrinsic rhythm, nominal, and high-output LP pacing. Two LP patients (without S-ICD) received ECV during follow-up. No impact on performance or LP dislodgements were observed. Conclusion Combined LP and S-ICD therapy appears feasible in all animal experiments (n = 2) and in one human subject. No interference in sensing and pacing during intrinsic and paced rhythm was noted in both animal and human subjects. However, induced arrhythmia testing was not performed in the patient. Defibrillation therapy did not seem to affect LP function. More data on safety and performance are needed.Keywords
This publication has 20 references indexed in Scilit:
- Percutaneous Implantation of an Entirely Intracardiac Leadless PacemakerNew England Journal of Medicine, 2015
- Leadless Cardiac PacemakersJACC, 2015
- Early performance of a miniaturized leadless cardiac pacemaker: the Micra Transcatheter Pacing StudyEuropean Heart Journal, 2015
- State of the art of leadless pacingEP Europace, 2015
- Safety and Efficacy of the Totally Subcutaneous Implantable DefibrillatorJACC, 2015
- Chronic Performance of a Leadless Cardiac PacemakerJACC, 2015
- Worldwide experience with a totally subcutaneous implantable defibrillator: early results from the EFFORTLESS S-ICD RegistryEuropean Heart Journal, 2014
- Safety and Efficacy of a Totally Subcutaneous Implantable-Cardioverter DefibrillatorCirculation, 2013
- An Entirely Subcutaneous Implantable Cardioverter–DefibrillatorNew England Journal of Medicine, 2010
- The Incidence and Risk Factors for Venous Obstruction After Implantation of Transvenous Pacing LeadsPacing and Clinical Electrophysiology, 2002