Fluticasone propionate/salmeterol hydrofluoroalkane via metered-dose inhaler with integrated dose counter: performance and patient satisfaction
Authors:
- 8 September 2006
- journal article
- clinical trial
- Published by Hindawi Limited in International Journal Of Clinical Practice
- Vol. 60 (10) , 1218-1224
Abstract
Currently, patients have to keep track of doses to determine when to replace their metered-dose inhalers (MDIs). This study evaluated the performance and patient satisfaction of a novel MDI with an integrated dose counter. In an open-label study at 38 outpatient centres, patients > or =12 years old with asthma or chronic obstructive pulmonary disease (COPD) received two actuations of fluticasone propionate/salmeterol 125/25 microg (115/21 microg ex-actuator) hydrofluoroalkane (ADVAIR) HFA) via MDI with counter twice a day until all 120 actuations were completed. Concordance between counter and diary recordings in patients who reported use of > or =90% of labelled actuations (completer population, n = 228) was high (discrepancy rate of 0.94%) and the incidence of device firing without changes in counter readings was low (0.13%). Mean expected actuations based on canister weights (114) were slightly lower than mean counter (121) and diary reported actuations (120). Upon study completion, 95% of patients were satisfied with the dose counter and 92% agreed it would help prevent them from running out of medication. Safety assessments (intent-to-treat population, n = 237) indicated that the drug was well tolerated. This integrated MDI counter may help patients maintain better disease control by enabling them to accurately track their medication supply.Keywords
This publication has 14 references indexed in Scilit:
- How Do Patients Determine That Their Metered-Dose Inhaler Is Empty?Chest, 2004
- Inhaled Corticosteroids in Chronic Obstructive Pulmonary Disease and Risk of Death and HospitalizationAmerican Journal of Respiratory and Critical Care Medicine, 2003
- The misconception of using floating patterns as an accurate means of measuring the contents of metered-dose inhaler devicesAnnals of Allergy, Asthma & Immunology, 2001
- Measurement of children's asthma medication adherence by self report, mother report, canister weight, and Doser CTAnnals of Allergy, Asthma & Immunology, 2000
- Reliability of the model MC-311 MDI ChronologJournal of Allergy and Clinical Immunology, 1999
- Reliability of the Medtrac MDI Chronolog☆☆☆★★★Journal of Allergy and Clinical Immunology, 1997
- Noncompliance and treatment failure in children with asthmaJournal of Allergy and Clinical Immunology, 1996
- The Continued Need for Metered Dose InhalersJournal of Aerosol Medicine, 1995
- An Economic Evaluation of Asthma in the United StatesNew England Journal of Medicine, 1992
- Compliance of patients with asthma with an experimental aerosolized medication: Implications for controlled clinical trialsJournal of Allergy and Clinical Immunology, 1986