Multishot diffusion‐weighted SPLICE PROPELLER MRI of the abdomen
Open Access
- 21 April 2008
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 59 (5) , 947-953
Abstract
Multishot FSE (fast spin echo)‐based diffusion‐weighted (DW)‐PROPELLER (periodically rotated overlapping parallel lines with enhanced reconstruction) MRI offers the potential to reduce susceptibility artifacts associated with single‐shot DW‐EPI (echo‐planar imaging) approaches. However, DW‐PROPELLER in the abdomen is challenging due to the large field‐of‐view and respiratory motion during DW preparation. Incoherent signal phase due to motion will violate the Carr‐Purcell‐Meiboom‐Gill (CPMG) conditions, leading to destructive interference between spin echo and stimulated echo signals and consequent signal cancellation. The SPLICE (split‐echo acquisition of FSE signals) technique can mitigate non‐CPMG artifacts in FSE‐based sequences. For SPLICE, spin echo and stimulated echo are separated by using imbalanced readout gradients and extended acquisition window. Two signal families each with coherent phase properties are acquired at different intervals within the readout window. Separate reconstruction of these two signal families can avoid destructive phase interference. Phantom studies were performed to validate signal phase properties with different initial magnetization phases. This study evaluated the feasibility of combining SPLICE and PROPELLER for DW imaging of the abdomen. It is demonstrated that DW‐SPLICE‐PROPELLER can effectively mitigate non‐CPMG artifacts and improve DW image quality and apparent diffusion coefficient (ADC) map homogeneity. Magn Reson Med 59:947–953, 2008.Keywords
This publication has 17 references indexed in Scilit:
- Lung Carcinoma: Diffusion-weighted MR Imaging—Preliminary Evaluation with Apparent Diffusion CoefficientRadiology, 2007
- Functional MR Imaging Assessment of Tumor Response after 90Y Microsphere Treatment in Patients with Unresectable Hepatocellular CarcinomaJournal of Vascular and Interventional Radiology, 2007
- Multishot Diffusion-Weighted PROPELLER Magnetic Resonance Imaging of the AbdomenInvestigative Radiology, 2006
- Evaluation of hepatic lesions and hepatic parenchyma using diffusion‐weighted echo‐planar MR with three values of gradient b‐factorJournal of Magnetic Resonance Imaging, 2006
- Diffusion-weighted MR Imaging for Determination of Hepatocellular Carcinoma Response to Yttrium-90 RadioembolizationJournal of Vascular and Interventional Radiology, 2006
- Turboprop: Improved PROPELLER imagingMagnetic Resonance in Medicine, 2006
- Quantification of tumor tissue populations by multispectral analysisMagnetic Resonance in Medicine, 2004
- Improved Image Quality and Detection of Acute Cerebral Infarction with PROPELLER Diffusion-weighted MR ImagingRadiology, 2002
- On the application of ultra-fast rare experimentsMagnetic Resonance in Medicine, 1992
- Measurement of the self-diffusion coefficient of each component in a complex system using pulsed-gradient fourier transform NMRJournal of Magnetic Resonance (1969), 1973