THE SAFETY AND EFFICACY OF PASSIVE REMOVAL OF SILICONE OIL WITH 23-GAUGE TRANSCONJUNCTIVAL SUTURELESS SYSTEM
Authors:
- Sourabh D PatwardhanSPSourabh D Patwardhan
- Rajvardhan AzadRARajvardhan Azad
- Vinit ShahVSVinit Shah
- Yograj SharmaYSYograj Sharma
- 1 September 2010
- journal article
- research article
- Published by Wolters Kluwer Health in Retina
- Vol. 30 (8) , 1237-1241
Abstract
To evaluate the safety and efficacy of passive removal of silicone oil with 23-gauge (G) transconjunctival sutureless system. This is a single-center, prospective, interventional, randomized control study. Forty eyes of 40 patients were enrolled in this study and randomized into 2 groups. Group 1 (n = 20) patients underwent passive removal of silicone oil with 23-G transconjunctival sutureless system. Group 2 (n = 20) underwent 20-G active silicone oil removal using all three 20-G ports. In both groups, air-fluid exchange was performed and the globe was left air filled at the end of surgery. All eyes in both groups received 360 degrees endolaser. We recorded surgical time, time for silicone oil removal, number of sutured 23-G sclerotomy sites, presence of preoperative scarring at sclerotomy site, postoperative hypotony, endophthalmitis, and inflammation at sclerotomy site. Opening and closing times were significantly shorter in Group 1 than in Group 2. Only 3 cases (15%) in Group 1 required 1 additional suture each in the superior sclerotomy site. Both groups were similar in safety in terms of chance of endophthalmitis, redetachment rate, and postoperative hypotony. Only 1 patient of Group 1 (5%) and 5 patients of Group 2 (25%) showed significant conjunctival inflammation at the end of 2 weeks. Passive removal of silicone oil with 23-G transconjunctival sutureless system may hasten postoperative recovery by decreasing overall surgical time and postoperative inflammation. It is a safe and effective procedure when compared with 20-G active silicone oil removal for 1000 centistoke oil.Keywords
This publication has 13 references indexed in Scilit:
- TRANSCONJUNCTIVAL 20-GAUGE PARS PLANA VITRECTOMY USING A SINGLE ENTRY CANNULATED SUTURELESS SYSTEMRetina, 2009
- SILICONE OIL TAMPONADE IN 23-GAUGE TRANSCONJUNCTIVAL SUTURELESS VITRECTOMYRetina, 2007
- REMOVAL OF SILICONE OIL WITH 25-GAUGE TRANSCONJUNCTIVAL SUTURELESS VITRECTOMY SYSTEMRetina, 2007
- Active Removal of Silicone Oil With 25-Gauge Sutureless SystemRetina, 2007
- The Safety and Efficacy of Transconjunctival Sutureless 23-gauge VitrectomyKorean Journal of Ophthalmology, 2007
- Combined phacoemulsification, foldable intraocular lens implantation, and 25-gauge transconjunctival sutureless vitrectomyJournal of Cataract & Refractive Surgery, 2006
- Transconjunctival sutureless vitrectomy: initial experience and surgical tipsEye, 2006
- Outcomes of 140 Consecutive Cases of 25-Gauge Transconjunctival Surgery for Posterior Segment DiseaseOphthalmology, 2005
- A new 25-gauge instrument system for transconjunctival sutureless vitrectomy surgery1 1The new Transconjunctival Sutureless Vitrectomy System is disclosed to Bausch and Lomb Surgical, St. Louis, MO. The Microsurgery Advanced Design Laboratory (MADLAB) may receive royalties related to the sale of this and other instruments mentioned in the article.Ophthalmology, 2002
- Initial experience using the transconjunctival sutureless vitrectomy system for vitreoretinal surgery1 1The new Transconjunctival Sutureless Vitrectomy System is disclosed to Bausch & Lomb Surgical, St. Louis, MO. The Microsurgery Advanced Design Laboratory (MADLAB) may receive royalties related to the sale of this and other instruments mentioned in the article.Ophthalmology, 2002