Comprehensive assessment of nuclear and cortical backscatter metrics derived from rotating Scheimpflug images
- 12 October 2012
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 38 (12) , 2100-2107
Abstract
To quantify cataract in lens-backscatter metrics derived from Pentacam Scheimpflug photographs and determine the most predictive metrics for lens grading and visual performance measures. Large tertiary referral hospital in South Australia. Evaluation of diagnostic test or technology. In patients attending a cataract clinic between 2005 and 2008, standardized clinical assessments were performed and Scheimpflug photographs taken. Thirteen measures of cataract backscatter were drawn from the images of nuclear and cortical cataract, including new metrics for cortical cataract. The relationships between lens-scatter metrics, visual performance, and lens grades were determined with stepwise multiple linear regression. The study enrolled 342 eyes (177 patients). The Lens Opacities Classification System III (LOCS III) nuclear opalescence was best predicted by the average backscatter in the anterior half of the nucleus and the whole nucleus average (r2 = 0.59). The LOCS III cortical grade was best predicted by the number of slices with significant cortical cataract (r2 = 0.52), as was Pelli-Robson contrast sensitivity (r2 = 0.16). Visual acuity was best predicted by the combined anterior half and whole nucleus averages (r2 = 0.20). Pelli-Robson contrast sensitivity under glare was best predicted by a combination of the anterior half and whole nucleus averages and the calculated percentage of cortical cataract (r2 = 0.16). Scheimpflug image–derived metrics of nuclear scatter were predictive of visual acuity and contrast sensitivity, whereas metrics of cortical cataract were predictive of visual performance under glare. Automated reporting of cataract severity from Scheimpflug images could be useful clinically and should include measurements of cortical cataract. Neither author has a financial or proprietary interest in any material or method mentioned.Keywords
This publication has 7 references indexed in Scilit:
- Correlation of Nuclear Cataract Lens Density Using Scheimpflug Images with Lens Opacities Classification System III and Visual FunctionOphthalmology, 2009
- Grading nuclear cataract opacity by densitometry and objective optical analysisJournal of Cataract & Refractive Surgery, 2008
- Correlation of lens density measured using the Pentacam Scheimpflug system with the Lens Opacities Classification System III grading score and visual acuity in age-related nuclear cataractBritish Journal of Ophthalmology, 2008
- Universal Opacity Standard for Scheimpflug PhotographyOphthalmic Research, 2000
- An Index for Human Lens Transparency Related to Age and Lens Layer: Comparison between Normal Volunteers and Diabetic Patients with Still Clear LensesOphthalmic Research, 1999
- Comparison of Clinical and Digital Assessment of Nuclear Optical DensityOphthalmic Research, 1999
- The effect of pupil and observation distance on the contrast sensitivity functionOphthalmic and Physiological Optics, 1996