Optimizing the Sample Size and the Reduced Velocity To Achieve Maximum Production Rates of Enantiomers
- 1 November 1992
- journal article
- Published by Wiley in Biotechnology Progress
- Vol. 8 (6) , 533-539
Abstract
Optimum experimental conditions are predicted for the maximum production rate of D‐ or L‐alanine, purified to a 99% purity from a racemic mixture of their N‐benzoyl derivatives by preparative chromatography on ionically immobilized bovine serum albumin. The experimental production rates and recovery yields measured under these conditions are in excellent agreement with the calculated values. These results validate the approach used for optimization of preparative liquid chromatography.Keywords
This publication has 24 references indexed in Scilit:
- Optimization of the experimental conditions and the column design parameters in overloaded elution chromatographyJournal of Chromatography A, 1992
- Comparison of the performances of overloaded elution and displacement chromatography for a given columnJournal of Chromatography A, 1991
- Isotherm selection for band profile simulations in preparative chromatographyAIChE Journal, 1991
- Optimization of experimental conditions in preparative liquid chromatographyJournal of Chromatography A, 1991
- Dependence of the production rate on the relative retention of two components in preparative chromatographyJournal of Chromatography A, 1990
- Solutions of the equilibrium and semi-equilibrium models of chromatographyJournal of Chromatography A, 1990
- Direct liquid chromatographic separation of enantiomers on immobilized protein stationary phasesJournal of Chromatography A, 1990
- A simplex optimization of the experimental parameters in preparative liquid chromatographyChromatographia, 1988
- Direct liquid chromatographic separation of enantiomers on immobilized protein stationary phasesJournal of Chromatography A, 1983
- Direct resolution of enantiomers by liquid affinity chromatography on albumin-agarose under isocratic conditionsJournal of Chromatography A, 1982