Comparative Use of Quantitative PCR (qPCR), Droplet Digital PCR (ddPCR), and Recombinase Polymerase Amplification (RPA) in the Detection of Shiga Toxin-Producing E. coli (STEC) in Environmental Samples
Open Access
Abstract
E. coli O157:H7 is a foodborne pathogen that constitutes a global threat to human health. However, the quantification of this pathogen in food and environmental samples may be problematic at the low cell numbers commonly encountered in environmental samples. In this study, we used recombinase polymerase amplification (RPA) for the detection of E. coli O157:H7, real-time quantitative PCR (qPCR) for quantification, and droplet digital PCR (ddPCR) for absolute and accurate quantification of E. coli O157:H7 from spiked and environmental samples. Primer and probe sets were used for the detection of stx1 and stx2 using RPA. Genes encoding for stx1, stx2, eae, and rfbE were used to quantify E. coli O157:H7 in the water samples. Furthermore, duplex ddPCR assays were used to quantify the pathogens in these samples. Duplex assay set 1 used stx1 and rfbE genes, while assay set 2 used stx2 and eae genes. Droplet digital PCR was used for the absolute quantification of E. coli O15:H7 in comparison with qPCR for the spiked and environmental samples. The RPA results were compared to those from qPCR and ddPCR in order to assess the efficiency of the RPA compared with the PCR methods. The assays were further applied to the dairy lagoon effluent (DLE) and the high rate algae pond (HRAP) effluent, which were fed with diluted DLE. The RPA detected was 4 CFU/mL with a high reproducibility. In addition, quantification by qPCR was from 103 to 107 CFU/mL of the wastewater samples. Therefore, the RPA assay has potential as a point of care tool for the detection of E. coli O157:H7 from different environmental sources, followed by quantification of the target concentrations.Keywords
Funding Information
- Agricultural Research Service (036012036505)
This publication has 38 references indexed in Scilit:
- Quantitative Analysis of Food and Feed Samples with Droplet Digital PCRPLOS ONE, 2013
- Methods for Applying Accurate Digital PCR Analysis on Low Copy DNA SamplesPLOS ONE, 2013
- Comparison of microfluidic digital PCR and conventional quantitative PCR for measuring copy number variationNucleic Acids Research, 2012
- Evaluation of a Multiplex Real-Time Polymerase Chain Reaction for the Quantification of Escherichia coli O157 in Cattle FecesFoodborne Pathogens and Disease, 2012
- Variability of Escherichia coli O157 Strain Survival in Manure-Amended Soil in Relation to Strain Origin, Virulence Profile, and Carbon Nutrition ProfileApplied and Environmental Microbiology, 2011
- High-Throughput Droplet Digital PCR System for Absolute Quantitation of DNA Copy NumberAnalytical Chemistry, 2011
- Persistence of Escherichia coli O157:H7 and Its Mutants in SoilsPLOS ONE, 2011
- Incidence and Tracking of Escherichia coli O157:H7 in a Major Produce Production Region in CaliforniaPLOS ONE, 2007
- Isogenic Strain of Escherichia coli O157:H7 That Has Lost both Shiga Toxin 1 and 2 GenesClinical and Diagnostic Laboratory Immunology, 2001
- Kinetic PCR Analysis: Real-time Monitoring of DNA Amplification ReactionsNature Biotechnology, 1993