New generation of highly sensitive radon detectors based on activated carbon with compensated temperature dependence
Open Access
- 19 May 2022
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-9
Abstract
Recently patented compensation module for sensors of radioactive noble gases paves the way for novel designs of radon detectors/monitors with adsorbents, suitable for long-term measurements. The module compensates the strong influence of the temperature on the response of detectors with activated carbon or other ad/absorbents. This report describes radon detectors in which activated carbon fabric is coupled with a solid state nuclear track detector and placed in a compensation module. The module is a hermetic volume made of polyethylene foil, through which the radon diffuses. Two reciprocal trends make possible the temperature compensation: that of the radon penetration through the walls, which increases with the increase of the temperature, and that of the adsorption, which decreases. The results show that outside the module the variation of the detector response over the range of 5–35 °C is 230–305%. In contrast, inside the module the variation is reduced to 6–17%. The module also protects the sensor from humidity and thoron, keeping its sensitivity to radon 7–9 times higher than that of commonly used radon detectors. This makes the new detectors very useful for measurement of low radon concentrations in the atmosphere.Keywords
Funding Information
- Bulgarian National Science Fund (KP-06-458/9 (22.11.2021))
This publication has 21 references indexed in Scilit:
- Laboratory facility to create reference radon + thoron atmosphere under dynamic exposure conditionsJournal of Environmental Radioactivity, 2017
- Temperature calibration formula for activated charcoal radon collectorsJournal of Environmental Radioactivity, 2011
- Why is 220Rn (thoron) measurement important?Radiation Protection Dosimetry, 2010
- Radon-film-badges by solid radiators to complement track detector-based radon monitorsRadiation Measurements, 2009
- Membrane-based thermal effects in 222Rn dosimetryRadiation Measurements, 2000
- A passive radon dosimeter based on the combination of a track etch detector and activated charcoalRadiation Measurements, 1999
- Studies on radon adsorption characteristics of different charcoals used as amplifiers for the track detectorsRadiation Measurements, 1999
- A new technique for radon measurement based on a combination of a track-etch detector and activated charcoalInternational Journal of Radiation Applications and Instrumentation. Part D. Nuclear Tracks and Radiation Measurements, 1991
- Adsorption and Desorption of Noble Gases on Activated CharcoalHealth Physics, 1990
- Theory and Practice of Radon Monitoring With Charcoal AdsorptionHealth Physics, 1983