Measurements of radiation fields from a ceramic break
Authors:
Open Access
- 1 January 2023
- conference paper
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2420 (1)
Abstract
Ceramic breaks are used in synchrotrons for many purposes. For example, they are inserted between the Multi-Wire Profile Monitor (MWPM) on the injection line at the Rapid Cycling Synchrotron (RCS) in J-PARC to completely prevent the wall currents accompanying beams from affecting the MWPM. On the other hand, from the viewpoint of suppressing beam impedances and the radiation fields from the ceramic breaks, it would be preferable that the inner surface of the ceramic break is coated with Titanium Nitride (TiN), or covered over capacitors. In this report, we measure the radiation fields from the ceramic break with and without capacitors as well as the beam profile and investigate the effect of the ceramic breaks on the measurements.Keywords
This publication has 3 references indexed in Scilit:
- Titanium nitride-coated ceramic break for wall current monitors with an improved broadband frequency responsePhysical Review Accelerators and Beams, 2020
- Realizing a high-intensity low-emittance beam in the J-PARC 3-GeV RCSJournal of Physics: Conference Series, 2017
- Achievement of a low-loss 1-MW beam operation in the 3-GeV rapid cycling synchrotron of the Japan Proton Accelerator Research ComplexPhysical Review Accelerators and Beams, 2017