A quantum dot-based fluorescence sensor for sensitive and enzymeless detection of creatinine
- 23 June 2016
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 8 (30) , 5911-5920
Abstract
In this paper, we report a novel “turn-on” fluorescence sensor for selective and sensitive determination of creatinine (Crn) in human serum and urine samples, using thioglycolic acid (TGA) capped ZnS:Mn/ZnS quantum dots (QDs). TGA capped ZnS:Mn/ZnS QDs have been synthesized via a facile aqueous co-precipitation method and characterized by fluorescence, UV-vis absorption, Fourier transform infrared spectroscopy (FT-IR), transmission electron microscopy (TEM), X-ray diffraction (XRD), dynamic light scattering (DLS) measurements and energy-dispersive X-ray spectroscopy (EDS). The fluorescence emission spectrum of TGA functionalized ZnS:Mn/ZnS QDs showed a significant increase in emission intensity in the presence of Crn. The enhancement in emission is due to passivation of the surface trap states of QDs through the binding of Crn with the QD surface, which results in the formation of new radiative electron–hole recombination centers. The interaction between Crn and QDs was investigated by some analytical techniques such as fluorescence, UV-vis spectroscopy and DLS measurements. Under the optimum conditions the probe offers a good linear relationship between 0.07 and 3.4 μM for Crn with the correlation coefficient (R2) of 0.9963 and limit of detection (LOD) and limit of quantification (LOQ) of 7.25 nM and 0.0242 μM, respectively. The method was successfully employed for the analysis of the Crn content in human serum and urine. The proposed method demonstrated several advantages such as high sensitivity, short analysis time, low cost and ease of operation.Keywords
This publication has 47 references indexed in Scilit:
- Band gap determination using absorption spectrum fitting procedureInternational Nano Letters, 2013
- Rapid Determination of Creatinine in Human Urine by Microchip Electrophoresis with LED Induced Fluorescence DetectionChromatographia, 2012
- Quantification of creatinine in biological samples based on the pseudoenzyme activity of copper–creatinine complexSpectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2012
- Quantum Dot Enabled Molecular Sensing and DiagnosticsTheranostics, 2012
- Aqueous, Protein-Driven Synthesis of Transition Metal-Doped ZnS Immuno-Quantum DotsACS Nano, 2011
- Quantitative Determination of Sarcosine and Related Compounds in Urinary Samples by Liquid Chromatography with Tandem Mass SpectrometryAnalytical Chemistry, 2010
- The extraction of creatinine from a physiological medium by a microporous solid and its quantification by diffuse reflectance UV spectroscopyMicroporous and Mesoporous Materials, 2010
- Point of care measurement of plasma creatinine in critically ill patients with acute kidney injuryAnaesthesia, 2009
- Infrared spectra of Pt(II) creatinine complexes. Normal coordinate analysis of creatinine and Pt(creat)2(NO2)2Spectrochimica Acta Part A: Molecular Spectroscopy, 1991
- THE EQUILIBRIUM BETWEEN CREATINE AND CREATININE, IN AQUEOUS SOLUTION. THE EFFECT OF HYDROGEN IONJournal of the American Chemical Society, 1925