Optimization of pulsed focused ultrasound exposures for hyperthermia applications
Authors:
- 1 July 2011
- journal article
- research article
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 130 (1) , 599-609
Abstract
Hyperthermic temperatures, with potential applications in drug/gene delivery and chemo/radio sensitization, may be generated in biological tissues by applying focused ultrasound (FUS) in pulsed mode. Here, a strategy for optimizing FUS exposures for hyperthermia applications is proposed based on theoretical simulations and in vitro experiments. Initial simulations were carried out for tissue-mimicking phantoms, and subsequent thermocouple measurements allowed for validation of the simulation results. Advanced simulations were then conducted for an ectopic, murine xenograft tumor model. The ultrasound exposure parameters investigated in this study included acoustic power (3–5 W), duty cycle (DC) (10%–50%), and pulse repetition frequency (PRF) (1–5 Hz), as well as effects of tissue perfusion. The thermocouple measurements agreed well with simulation outcomes, where differences between the two never exceeded 1.9%. Based on a desired temperature range of 39–44 °C, optimal tumor coverage (40.8% of the total tumor volume) by a single FUS exposure at 1 MHz was achieved with 4 W acoustic power, 50% DC, and 5 Hz PRF. Results of this study demonstrate the utility of a proposed strategy for optimizing pulsed-FUS induced hyperthermia. These strategies can help reduce the requirement for empirical animal experimentation, and facilitate the translation of pulsed-FUS applications to the clinic.Keywords
This publication has 40 references indexed in Scilit:
- Hyperthermia combined with radiation for the treatment of locally advanced prostate cancerCancer, 2010
- Activation of transgene expression in skeletal muscle by focused ultrasoundBiochemical and Biophysical Research Communications, 2009
- Image-guided, noninvasive, spatiotemporal control of gene expressionProceedings of the National Academy of Sciences, 2009
- In vitro and in vivo evaluations of increased effective beam width for heat deposition using a split focus high intensity ultrasound (HIFU) transducerInternational Journal of Hyperthermia, 2008
- Pulsed-High Intensity Focused Ultrasound and Low Temperature–Sensitive Liposomes for Enhanced Targeted Drug Delivery and Antitumor EffectClinical Cancer Research, 2007
- Preliminary Experience Using High Intensity Focused Ultrasound for the Treatment of Patients With Advanced Stage Renal MalignancyJournal of Urology, 2003
- Effect of Vessel Size on Creation of Hepatic Radiofrequency Lesions in PigsAmerican Journal of Roentgenology, 2002
- Blood flow changes in transplanted mouse tumours and skin after mild hyperthermiaBritish Journal of Radiology, 1983
- TEMPERATURE RANGE AND SELECTIVE SENSITIVITY OF TUMORS TO HYPERTHERMIA: A CRITICAL REVIEWAnnals of the New York Academy of Sciences, 1980
- INFLUENCE OF BLOOD SUPPLY ON THERMAL PROPERTIES AND METABOLISM OF MAMMARY CARCINOMASAnnals of the New York Academy of Sciences, 1980