Scan–Rescan Repeatability and Impact of B0 and B1 Field Nonuniformity Corrections in Single‐Point Whole‐Brain Macromolecular Proton Fraction Mapping
- 18 November 2019
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 51 (6) , 1789-1798
Abstract
Background: Single‐point macromolecular proton fraction (MPF) mapping is a recent quantitative MRI method for fast assessment of brain myelination. Information about reproducibility and sensitivity of MPF mapping to magnetic field nonuniformity is important for clinical applications.Purpose: To assess scan–rescan repeatability and a value of B0 and B1 field inhomogeneity corrections in single‐point synthetic‐reference MPF mapping.Study Type: Prospective.Population: Eight healthy adult volunteers underwent two scans with 11.5 ± 2.3 months interval.Field Strength/Sequence: 3T; whole‐brain 3D MPF mapping protocol included three spoiled gradient‐echo sequences providing T1, proton density, and magnetization transfer contrasts with 1.25 × 1.25 × 1.25 mm3 resolution and B0 and B1 mapping sequences.Assessment: MPF maps were reconstructed with B0 and B1 field nonuniformity correction, B0‐ and B1‐only corrections, and without corrections. Mean MPF values were measured in automatically segmented white matter (WM) and gray matter (GM).Statistical Tests: Within‐subject coefficient of variation (CV), intraclass correlation coefficient (ICC), Bland–Altman plots, and paired t‐tests to assess scan–rescan repeatability. Repeated‐measures analysis of variance (ANOVA) to compare field corrections.Results: Maximal relative local MPF errors without correction in the areas of largest field nonuniformities were about 5% and 27% for B0 and B1, respectively. The effect of B0 correction was insignificant for whole‐brain WM (P > 0.25) and GM (P > 0.98) MPF. The absence of B1 correction caused a positive relative bias of 4–5% (P < 0.001) in both tissues. Scan–rescan agreement was similar for all field correction options with ICCs 0.80–0.81 for WM and 0.89–0.92 for GM. CVs were 1.6–1.7% for WM and 0.7–1.0% for GM.Data Conclusion: The single‐point method enables high repeatability of MPF maps obtained with the same equipment. Correction of B0 inhomogeneity may be disregarded to shorten the examination time. B1 nonuniformity correction improves accuracy of MPF measurements at 3T. Reliability of whole‐brain MPF measurements in WM and GM is not affected by B0 and B1 field corrections.Level of Evidence: 2Technical Efficacy: Stage 1J. Magn. Reson. Imaging 2020;51:1789–1798.Keywords
Funding Information
- Ministry of Education and Science of the Russian Federation (18.2583.2017/4.6)
- National Institute of Neurological Disorders and Stroke (R24NS104098‐01A1)
- National Multiple Sclerosis Society (RG4864A1/1)
- Russian Science Foundation (19‐75‐20142)
This publication has 39 references indexed in Scilit:
- Direct comparison between apparent diffusion coefficient and macromolecular proton fraction as quantitative biomarkers of the human fetal brain maturationJournal of Magnetic Resonance Imaging, 2019
- Quantitative Assessment of Normal Fetal Brain Myelination Using Fast Macromolecular Proton Fraction MappingAmerican Journal of Neuroradiology, 2018
- Iron-Insensitive Quantitative Assessment of Subcortical Gray Matter Demyelination in Multiple Sclerosis Using the Macromolecular Proton FractionAmerican Journal of Neuroradiology, 2018
- Quantitative assessment of demyelination in ischemic stroke in vivo using macromolecular proton fraction mappingJournal of Cerebral Blood Flow & Metabolism, 2018
- Histological validation of fast macromolecular proton fraction mapping as a quantitative myelin imaging method in the cuprizone demyelination modelScientific Reports, 2017
- Time-efficient, high-resolution, whole brain three-dimensional macromolecular proton fraction mappingMagnetic Resonance in Medicine, 2015
- Fast Whole-Brain Three-dimensional Macromolecular Proton Fraction Mapping in Multiple SclerosisRadiology, 2015
- Neuroimaging, Behavioral, and Psychological Sequelae of Repetitive Combined Blast/Impact Mild Traumatic Brain Injury in Iraq and Afghanistan War VeteransJournal of Neurotrauma, 2014
- Fast macromolecular proton fraction mapping from a single off‐resonance magnetization transfer measurementMagnetic Resonance in Medicine, 2011
- Fast bound pool fraction imaging of the in vivo rat brain: Association with myelin content and validation in the C6 glioma modelNeuroImage, 2011