Normal Values for the Full Visual Field, Corrected for Age- and Reaction Time, Using Semiautomated Kinetic Testing on the Octopus 900 Perimeter
Open Access
- 1 March 2016
- journal article
- research article
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 5 (2) , 5
Abstract
Purpose: To determine normal values of the visual field (VF), corrected for age and reaction time (RT) for semiautomated kinetic perimetry (SKP) on the Octopus 900 perimeter, create a model describing the age-dependency of these values, and assess test–retest reliability for each isopter. Methods: Eighty-six eyes of 86 ophthalmologically healthy subjects (age 11–79 years, 34 males, 52 females) underwent full-field kinetic perimetry with the Octopus 900 instrument. Stimulus size, luminance, velocity, meridional angle, subject age, and their interactions, were used to create a smooth multiple regression mathematical model (V/4e, III/4e, I/4e, I/3e, I/2e, I/1e, and I/1a isopters). Fourteen subjects (2 from each of 7 age groups) were evaluated on three separate sessions to assess test–retest reliability of the isopters. Reaction time (RT) was tested by presenting 12 designated RT-vectors between 10° and 20° within the seeing areas for the III/4e isopter (stimulus velocity, 3°/second). Four RT- vectors were presented at the nasal (0° or 180°), superotemporal (45°), and inferior (270°) meridians. Results: The model fit was excellent (r2 = 0.94). The test–retest variability was less than 5°, and the median decrease in this deviation attributed to aging, per decade, for all age groups and for all stimulus sizes was 0.8°. No significant learning effect was observed for any age group or isopter. Conclusion: Age-corrected and RT-corrected normative threshold values for full-field kinetic perimetry can be adequately described by a smooth multiple linear regression mathematical model. Translational Relevance: A description of the entire kinetic VF is useful for assessing a full characterization of VF sensitivity, determining function losses associated with ocular and neurologic diseases, and for providing a more comprehensive analysis of structure–function relationships.Keywords
This publication has 35 references indexed in Scilit:
- Static versus kinetic testing in the nasal peripheral field in patients with glaucomaActa Ophthalmologica, 2009
- The Normal Age-Corrected and Reaction Time–Corrected Isopter Derived by Semi-automated Kinetic PerimetryOphthalmology, 2007
- Factors Influencing Reaction Time during Automated Kinetic Perimetry on the Tübingen Computer CampimeterInvestigative Ophthalmology & Visual Science, 2005
- Visual Field of High-Pass Resolution Perimetry in Normal SubjectsJournal of Glaucoma, 2004
- Normal Isopter Position in the Peripheral Visual Field in Goldmann Kinetic PerimetryOphthalmologica, 2002
- Photoreceptor topography in ageing and age-related maculopathyEye, 2001
- Evaluation ausgedehnter Gesichtsfelddefekte mittels computerassistierter kinetischer Perimetrie123Klinische Monatsblätter für Augenheilkunde, 2001
- Aging and degeneration of the human macula. 1. Outer nuclear layer and photoreceptors.British Journal of Ophthalmology, 1981
- Naso-temporal differences in human reaction time in the peripheral visual fieldNeuropsychologia, 1978
- Kinetische PerimetrieOphthalmologica, 1969