Field experience with pressure-based leakage characterisation of bulk water pipelines
Authors:
- 26 November 2019
- journal article
- research article
- Published by Taylor & Francis in Urban Water Journal
- Vol. 16 (10) , 709-717
Abstract
A novel pressure-based leakage assessment and characterisation method was applied to a range of bulk pipelines in the field to evaluate the practical application of the method. With this method, the testing equipment, which consists of a variable speed pump unit, a water tank and measuring equipment, all mounted on a trailer, was connected to a bulk pipe which could be isolated. Flow was then introduced and regulated to maintain a range of set pressures, resulting in a pressure-leakage characteristic of the pipe. The test data was then interpreted using the modified orifice equation or FAVAD (Fixed and Varying Areas Discharges) concept. Fifteen pipes were assessed of which most showed significant or excessive leakage. By characterising the leakage of these pipes, useful information was obtained on the most likely leak types, sizes and possible locations. It was demonstrated that this is an effective, simple, quick and cost-effective leakage assessment method.Keywords
This publication has 17 references indexed in Scilit:
- A physically-based analytical relationship for practical prediction of leakage in longitudinally cracked pressurized pipesEngineering Structures, 2014
- Modeling Elastically Deforming Leaks in Water Distribution PipesJournal of Hydraulic Engineering, 2014
- Theoretical Modeling of Pressure and Leakage in Water Distribution SystemsProcedia Engineering, 2014
- Implications of the Known Pressure-response of Individual Leaks for Whole Distribution SystemsProcedia Engineering, 2014
- Soil fluidisation outside leaks in water distribution pipes – preliminary observationsProceedings of the Institution of Civil Engineers - Water Management, 2013
- Predicting the head-leakage slope of cracks in pipes subject to elastic deformationsJournal of Water Supply: Research and Technology—AQUA, 2013
- Condition assessment of the buried utility service infrastructureTunnelling and Underground Space Technology, 2012
- Potential of Transient Tests to Diagnose Real Supply Pipe Systems: What Can Be Done with a Single Extemporary TestJournal of Water Resources Planning and Management, 2011
- A numerical investigation into the effect of pressure on holes and cracks in water supply pipesUrban Water Journal, 2010
- An experimental investigation into the pressure - leakage relationship of some failed water pipesJournal of Water Supply: Research and Technology—AQUA, 2007