Optimization and validation of accelerated golden‐angle radial sparse MRI reconstruction with self‐calibrating GRAPPA operator gridding
- 28 November 2017
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 80 (1) , 286-293
Abstract
Purpose: Golden‐angle radial sparse parallel (GRASP) MRI reconstruction requires gridding and regridding to transform data between radial and Cartesian k‐space. These operations are repeatedly performed in each iteration, which makes the reconstruction computationally demanding. This work aimed to accelerate GRASP reconstruction using self‐calibrating GRAPPA operator gridding (GROG) and to validate its performance in clinical imaging.Methods: GROG is an alternative gridding approach based on parallel imaging, in which k‐space data acquired on a non‐Cartesian grid are shifted onto a Cartesian k‐space grid using information from multicoil arrays. For iterative non‐Cartesian image reconstruction, GROG is performed only once as a preprocessing step. Therefore, the subsequent iterative reconstruction can be performed directly in Cartesian space, which significantly reduces computational burden. Here, a framework combining GROG with GRASP (GROG‐GRASP) is first optimized and then compared with standard GRASP reconstruction in 22 prostate patients.Results: GROG‐GRASP achieved approximately 4.2‐fold reduction in reconstruction time compared with GRASP (∼333 min versus ∼78 min) while maintaining image quality (structural similarity index ≈ 0.97 and root mean square error ≈ 0.007). Visual image quality assessment by two experienced radiologists did not show significant differences between the two reconstruction schemes. With a graphics processing unit implementation, image reconstruction time can be further reduced to approximately 14 min.Conclusion: The GRASP reconstruction can be substantially accelerated using GROG. This framework is promising toward broader clinical application of GRASP and other iterative non‐Cartesian reconstruction methods. Magn Reson Med 80:286–293, 2018. © 2017 International Society for Magnetic Resonance in Medicine.Keywords
Funding Information
- NIH (P41 EB017183, R01 EB018308)
This publication has 35 references indexed in Scilit:
- Nonlinear inverse reconstruction for real‐time MRI of the human heart using undersampled radial FLASHMagnetic Resonance in Medicine, 2010
- Respiratory and cardiac self‐gated free‐breathing cardiac CINE imaging with multiecho 3D hybrid radial SSFP acquisitionMagnetic Resonance in Medicine, 2010
- Radial k‐t FOCUSS for high‐resolution cardiac cine MRIMagnetic Resonance in Medicine, 2009
- Acquisition and reconstruction of undersampled radial data for myocardial perfusion magnetic resonance imagingJournal of Magnetic Resonance Imaging, 2009
- Self‐calibrating GRAPPA operator gridding for radial and spiral trajectoriesMagnetic Resonance in Medicine, 2008
- A software channel compression technique for faster reconstruction with many channelsMagnetic Resonance Imaging, 2008
- Non‐Cartesian data reconstruction using GRAPPA operator gridding (GROG)Magnetic Resonance in Medicine, 2007
- Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraintMagnetic Resonance in Medicine, 2007
- Nonuniform fast fourier transforms using min-max interpolationIEEE Transactions on Signal Processing, 2003
- Projection Reconstruction Techniques for Reduction of Motion Effects in MRIMagnetic Resonance in Medicine, 1992