Quality assessment of high angular resolution diffusion imaging data using bootstrap on Q‐ball reconstruction
Open Access
- 21 April 2011
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 33 (5) , 1194-1208
Abstract
Purpose: To develop a bootstrap method to assess the quality of High Angular Resolution Diffusion Imaging (HARDI) data using Q‐Ball imaging (QBI) reconstruction. Materials and Methods: HARDI data were re‐shuffled using regular bootstrap with jackknife sampling. For each bootstrap dataset, the diffusion orientation distribution function (ODF) was estimated voxel‐wise using QBI reconstruction based on spherical harmonics functions. The reproducibility of the ODF was assessed using the Jensen‐Shannon divergence (JSD) and the angular confidence interval was derived for the first and the second ODF maxima. The sensitivity of the bootstrap method was evaluated on a human subject by adding synthetic noise to the data, by acquiring a map of image signal‐to‐noise ratio (SNR) and by varying the echo time and the b‐value. Results: The JSD was directly linked to the image SNR. The impact of echo times and b‐values was reflected by both the JSD and the angular confidence interval, proving the usefulness of the bootstrap method to evaluate specific features of HARDI data. Conclusion: The bootstrap method can effectively assess the quality of HARDI data and can be used to evaluate new hardware and pulse sequences, perform multifiber probabilistic tractography, and provide reliability metrics to support clinical studies. J. Magn. Reson. Imaging 2011;33:1194–1208.Keywords
This publication has 45 references indexed in Scilit:
- The effect of metric selection on the analysis of diffusion tensor MRI dataNeuroImage, 2010
- Quantitative assessment of motion correction for high angular resolution diffusion imagingMagnetic Resonance Imaging, 2010
- How does angular resolution affect diffusion imaging measures?NeuroImage, 2010
- Detection of multiple pathways in the spinal cord using q-ball imagingNeuroImage, 2008
- An optimized wild bootstrap method for evaluation of measurement uncertainties of DTI-derived parameters in human brainNeuroImage, 2008
- Effects of signal‐to‐noise ratio on the accuracy and reproducibility of diffusion tensor imaging–derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5TJournal of Magnetic Resonance Imaging, 2007
- A framework for quality control and parameter optimization in diffusion tensor imaging: theoretical analysis and validationMagnetic Resonance Imaging, 2007
- Confidence mapping in diffusion tensor magnetic resonance imaging tractography using a bootstrap approachMagnetic Resonance in Medicine, 2005
- Assessing DTI data quality using bootstrap analysisMagnetic Resonance in Medicine, 2004
- Diffusion tensor imaging: Concepts and applicationsJournal of Magnetic Resonance Imaging, 2001