Abstract
Summary: Objective: This study tested the hypothesis that lactate testing in ED sepsis patients could be increased using a computer alert that automatically recognizes systemic inflammatory response syndrome (SIRS) criteria and recommends lactate testing in cases of sepsis defined as ≥2 SIRS criteria plus physician suspicion of infection. Secondary outcomes included the effect of the alert on lactate testing among admitted sepsis patients, the proportion of admitted patients with lactate ≥4.0 mmol/L identified and the in-patient mortality difference before and after alert implementation. Methods: After a 6 month pre-alert phase, a computer alert was implemented that computed and displayed abnormal vital signs and white blood cell counts for all patients with >2 SIRS criteria and recommended testing lactate if an infection was suspected. Data for admitted patients was collected electronically on consecutive patients meeting sepsis criteria for 6 months before and 6 months after implementation of the alert. Results: There were a total of 5,796 subjects enrolled. Among all septic patients, lactate testing increased from 5.2% in the pre-alert phase to 12.7% in the alert phase, a 7.5% (95% CI 6.0 to 9.0%) absolute increase in lactate testing, p<0.001. Among the 1,798 admitted patients with sepsis, lactate testing increased from 15.3% to 34.2%, an 18.9% (95% CI 15.0 to 22.8%) absolute increase, p2 SIRS criteria while mortality among admitted sepsis patients remained unchanged.

This publication has 31 references indexed in Scilit: