Automated 3D Segmentation of Intraretinal Surfaces in SD-OCT Volumes in Normal and Diabetic Mice
- 1 September 2014
- journal article
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 3 (5) , 8
Abstract
To describe an adaptation of an existing graph-theoretic method (initially developed for human optical coherence tomography [OCT] images) for the three-dimensional (3D) automated segmentation of 10 intraretinal surfaces in mice scans, and assess the accuracy of the method and the reproducibility of thickness measurements. Ten intraretinal surfaces were segmented in repeat spectral domain (SD)-OCT volumetric images acquired from normal (n = 8) and diabetic (n = 10) mice. The accuracy of the method was assessed by computing the border position errors of the automated segmentation with respect to manual tracings obtained from two experts. The reproducibility was statistically assessed for four retinal layers within eight predefined regions using the mean and SD of the differences in retinal thickness measured in the repeat scans, the coefficient of variation (CV) and the intraclass correlation coefficients (ICC; with 95% confidence intervals [CIs]). The overall mean unsigned border position error for the 10 surfaces computed over 97 B-scans (10 scans, 10 normal mice) was 3.16 ± 0.91 μm. The overall mean differences in retinal thicknesses computed from the normal and diabetic mice were 1.86 ± 0.95 and 2.15 ± 0.86 μm, respectively. The CV of the retinal thicknesses for all the measured layers ranged from 1.04% to 5%. The ICCs for the total retinal thickness in the normal and diabetic mice were 0.78 [0.10, 0.92] and 0.83 [0.31, 0.96], respectively. The presented method (publicly available as part of the Iowa Reference Algorithms) has acceptable accuracy and reproducibility and is expected to be useful in the quantitative study of intraretinal layers in mice. The presented method, initially developed for human OCT, has been adapted for mice, with the potential to be adapted for other animals as well. Quantitative in vivo assessment of the retina in mice allows changes to be measured longitudinally, decreasing the need for them.Keywords
This publication has 35 references indexed in Scilit:
- Long-Term Characterization of Retinal Degeneration inrd1andrd10Mice Using Spectral Domain Optical Coherence TomographyInvestigative Ophthalmology & Visual Science, 2012
- Spectral-Domain Optical Coherence Tomography as a Noninvasive Method to Assess Damaged and Regenerating Adult Zebrafish RetinasInvestigative Ophthalmology & Visual Science, 2012
- Real-Time Imaging of Rabbit Retina with Retinal Degeneration by Using Spectral-Domain Optical Coherence TomographyPLOS ONE, 2012
- Automated segmentation by pixel classification of retinal layers in ophthalmic OCT imagesBiomedical Optics Express, 2011
- Spectral domain optical coherence tomography (SD‐OCT) assessment of the healthy female canine retina and optic nerveVeterinary Ophthalmology, 2011
- Reproducibility of Spectral-Domain Optical Coherence Tomography Total Retinal Thickness Measurements in MiceInvestigative Ophthalmology & Visual Science, 2010
- Spectral Domain Optical Coherence Tomography in Mouse Models of Retinal DegenerationInvestigative Ophthalmology & Visual Science, 2009
- Thickness Profiles of Retinal Layers by Optical Coherence Tomography Image SegmentationAmerican Journal of Ophthalmology, 2008
- QUANTIFICATION OF PHOTORECEPTOR LAYER THICKNESS IN NORMAL EYES USING OPTICAL COHERENCE TOMOGRAPHYRetina, 2006
- Quantitative Thickness Measurement of Retinal Layers Imaged by Optical Coherence TomographyAmerican Journal of Ophthalmology, 2005