Intermediate Results of iStent or iStent inject Implantation Combined with Cataract Surgery in a Real-World Setting: A Longitudinal Retrospective Study
Open Access
- 5 February 2019
- journal article
- research article
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 8 (1) , 87-100
Abstract
Introduction In this real-world, retrospective, comparative study we evaluated 6-month performance and safety in consecutive eyes following implantation of the iStent® or iStent inject® trabecular micro-bypass device with concomitant cataract surgery. Methods Performance outcomes included intraocular pressure (IOP) reduction; glaucoma medication reduction; proportions of eyes achieving an IOP of < 18, < 16, < 14, or < 12 mmHg; and proportions of eyes on 0, 1, 2, or ≥ 3 medications. Safety outcomes included adverse events, secondary surgeries, and best-corrected visual acuity (BCVA). Results A total of 73 eyes with open-angle glaucoma and cataract were included in the study; of these, 38 eyes were implanted with the iStent device and 35 were implanted with the iStent inject device. The two groups of patients had similar baseline characteristics, with the exception of mean age and medication burden (both higher in patients receiving the iStent inject device); over 90% of eyes in both groups had early glaucoma. At 6 months after surgery, mean IOP had fallen from 16.5 ± 3.9 to 13.9 ± 2.3 mmHg in eyes with the iStent implant (p < 0.001), and from 17.3 ± 3.0 to 12.7 ± 1.8 mmHg in those with the iStent inject implant (p < 0.001). This reduction was significantly greater in the iStent inject eyes than in the iStent eyes (26.6 vs. 15.8%) (p = 0.005). Significantly more eyes receiving the iStent inject device compared to the iStent device achieved an IOP of < 18 mmHg at 6 months post surgery (100 vs. 86.8%) (p = 0.033). Average medication usage was reduced from 1.8 to 0.4 medications in iStent eyes (p < 0.001) and from 2.3 to 0.4 medications in iStent inject eyes (p < 0.001). Over 70% of eyes in both groups became medication-free by 6 months post implantation. Adverse events in iStent eyes were mild and resulted in no sequelae; two iStent eyes underwent non-penetrating deep sclerectomy during follow-up. No complications or secondary surgeries were noted in iStent inject eyes. All eyes in both groups maintained or showed improved BCVA versus baseline. Conclusion Significant and safe IOP and medication reductions were observed after iStent or iStent inject implantation with concomitant cataract surgery. Trends toward greater effectiveness and fewer adverse events were observed with the iStent inject device compared with the iStent device. Funding Article processing charges were provided by Glaukos Corporation.Keywords
This publication has 54 references indexed in Scilit:
- The Ocular Surface of Glaucoma Patients Treated over the Long Term Expresses Inflammatory Markers Related to Both T-Helper 1 and T-Helper 2 PathwaysOphthalmology, 2008
- Persistence and Adherence With Topical Glaucoma TherapyAmerican Journal of Ophthalmology, 2005
- Perioperative Complications of Trabeculectomy in the Collaborative Initial Glaucoma Treatment Study (CIGTS)American Journal of Ophthalmology, 2005
- Trabecular bypass stents decrease intraocular pressure in cultured human anterior segmentsAmerican Journal of Ophthalmology, 2004
- The Aqueous Outflow System as a Mechanical PumpJournal of Glaucoma, 2004
- Factors for progression and glaucoma treatment: The Early Manifest Glaucoma TrialCurrent Opinion in Ophthalmology, 2004
- Reduction of Intraocular Pressure and Glaucoma ProgressionArchives of Ophthalmology (1950), 2002
- Surgical strategies for coexisting glaucoma and cataractOphthalmology, 2002
- The Ocular Hypertension Treatment StudyArchives of Ophthalmology (1950), 2002
- The advanced glaucoma intervention study (AGIS): 7. the relationship between control of intraocular pressure and visual field deteriorationAmerican Journal of Ophthalmology, 2000