Surges of Electroencephalogram Activity at the Time of Death: A Case Series
- 1 December 2009
- journal article
- research article
- Published by SAGE Publications in Journal of Palliative Medicine
- Vol. 12 (12) , 1095-1100
Abstract
Level of consciousness at the end of life in critically ill patients is poorly characterized. We report a case series of seven patients who were neurologically intact before the decision to withdraw care due to extensive systemic critical illness. As part of our end-of-life care protocol, bispectral index (BIS) monitor (Aspect Medical Systems, Newton, MA) or SEDline™ (Hospira, Lake Forest, IL) monitoring devices are placed on each patient to ensure adequate comfort. Both monitoring systems use an integer-based system (BIS or PSI, respectively) to reflect the level of consciousness/effect of anesthesia. In each case, loss of blood pressure, as monitored by indwelling arterial line, was followed by a decline is BIS/PSI activity followed by a transient spike in BIS/PSI activity that approached levels normally associated with consciousness. This spike in electroencephalogram (EEG) activity had short duration and the activity then declined to a level of activity associated with burst suppression. In one case of a patient who had a SEDLine™ device, we were able to capture and analyze the raw EEG signal, and confirm that the EEG waveform was not artifact, and in fact a high frequency waveform was present during the spike activity. We speculate that this level of BIS/SEDline™ activity is related to the cellullar loss of membrane polarization due to hypoxemia. We further speculate that since this increase in electrical activity occurred when there was no discernable blood pressure, patients who suffer “near death” experiences may be recalling the aggregate memory of the synaptic activity associated with this terminal but potentially reversible hypoxemia.Keywords
This publication has 12 references indexed in Scilit:
- Spurious bispectral index values due to electromyographic activityEuropean Journal of Anaesthesiology, 2004
- Artifact in the Bispectral Index in a Patient with Severe Ischemic Brain InjuryAnesthesia & Analgesia, 2004
- Falsely Increased Bispectral Index Values in a Series of Patients Undergoing Cardiac Surgery Using Forced-Air-Warming Therapy of the HeadAnesthesia & Analgesia, 2002
- Bispectral index monitoringAnesthesiology Clinics of North America, 2001
- Development and Clinical Application of Electroencephalographic Bispectrum MonitoringAnesthesiology, 2000
- Bispectral Index Increases and Decreases Are Not Always Signs of Inadequate AnesthesiaAnesthesiology, 2000
- Pacer-induced Artifact in the Bispectral Index during Cardiac SurgeryAnesthesiology, 1999
- Electroencephalographic Changes During Brief Cardiac Arrest in HumansAnesthesiology, 1990
- Functional recovery of cortical neurons as related to degree and duration of ischemiaAnnals of Neurology, 1983