The Effects of Ambulatory Accelerations on the Stability of a Magnetically Suspended Impeller for an Implantable Blood Pump
- 12 July 2016
- journal article
- Published by Wiley in Artificial Organs
- Vol. 40 (9) , 867-876
Abstract
This article describes the effects of ambulatory accelerations on the stability of a magnetically suspended impeller for use in implantable blood pumps. A magnetic suspension system is developed to control the radial position of a magnetic impeller using coils in the pump casing. The magnitude and periodicity of ambulatory accelerations at the torso are measured. A test rig is then designed to apply appropriate accelerations to the suspension system. Accelerations from 0 to 1 g are applied to the suspended impeller with ambulatory periodicity while the radial position of the impeller and power consumption of the suspension system are monitored. The test is carried out with the impeller suspended in air, water, and a glycerol solution to simulate the viscosity of blood. A model is developed to investigate the effects of the radial magnetic suspension system and fluid damping during ambulatory accelerations. The suspension system reduces the average displacement of the impeller suspended in aqueous solutions within its casing to 100 µm with a power consumption of below 2 W during higher magnitude ambulatory accelerations (RMS magnitude 0.3 g). The damping effect of the fluid is also examined and it is shown that buoyancy, rather than drag, is the primary cause of the damping at the low displacement oscillations that occur during the application of ambulatory accelerations to such a suspension system.Keywords
Funding Information
- National Institute for Health Research (II-LB-1111-20007)
This publication has 26 references indexed in Scilit:
- Design of a Centrifugal Blood Pump: Heart Turcica CentrifugalArtificial Organs, 2011
- Advanced Heart Failure Treated with Continuous-Flow Left Ventricular Assist DeviceNew England Journal of Medicine, 2009
- A Magnetically Levitated Centrifugal Blood Pump With a Simple‐structured Disposable Pump HeadArtificial Organs, 2008
- Third‐generation Blood Pumps With Mechanical Noncontact Magnetic BearingsArtificial Organs, 2006
- A Compact Highly Efficient and Low Hemolytic Centrifugal Blood Pump With a Magnetically Levitated ImpellerArtificial Organs, 2006
- Numerical simulation of cardiovascular dynamics with healthy and diseased heart valvesJournal of Biomechanics, 2006
- Quantitative Evaluation of Blood Damage in a Centrifugal VAD by Computational Fluid DynamicsJournal of Fluids Engineering, 2004
- The HeartMate III: Design and In Vivo Studies of a Maglev Centrifugal Left Ventricular Assist DeviceArtificial Organs, 2001
- Using Hybrid Magnetic Bearings to Completely Suspend the Impeller of a Ventricular Assist DeviceArtificial Organs, 1996
- System modeling and control design of a horizontal-shaft magnetic-bearing systemIEEE Transactions on Magnetics, 1986