Correlative mass spectrometry imaging, applying time‐of‐flight secondary ion mass spectrometry and atmospheric pressure matrix‐assisted laser desorption/ionization to a single tissue section
Open Access
- 19 December 2017
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 32 (2) , 159-166
Abstract
Rationale: Mass spectrometry imaging (MSI) is a powerful tool for mapping the surface of a sample. Time‐of‐flight secondary ion mass spectrometry (TOF‐SIMS) and atmospheric pressure matrix‐assisted laser desorption/ionization (AP‐MALDI) offer complementary capabilities. Here, we present a workflow to apply both techniques to a single tissue section and combine the resulting data for the example of human colon cancer tissue. Methods: Following cryo‐sectioning, images were acquired using the high spatial resolution (1 μm pixel size) provided by TOF‐SIMS. The same section was then coated with a para ‐nitroaniline matrix and images were acquired using AP‐MALDI coupled to an Orbitrap mass spectrometer, offering high mass resolution, high mass accuracy and tandem mass spectrometry (MS/MS) capabilities. Datasets provided by both mass spectrometers were converted into the open and vendor‐independent imzML file format and processed with the open‐source software MSiReader. Results: The TOF‐SIMS and AP‐MALDI mass spectra show strong signals of fatty acids, cholesterol, phosphatidylcholine and sphingomyelin. We showed a high correlation between the fatty acid ions detected with TOF‐SIMS in negative ion mode and the phosphatidylcholine ions detected with AP‐MALDI in positive ion mode using a similar setting for visualization. Histological staining on the same section allowed the identification of the anatomical structures and their correlation with the ion images. Conclusions: This multimodal approach using two MSI platforms shows an excellent complementarity for the localization and identification of lipids. The spatial resolution of both systems is at or close to cellular dimensions, and thus spatial correlation can only be obtained if the same tissue section is analyzed sequentially. Data processing based on imzML allows a real correlation of the imaging datasets provided by these two technologies and opens the way for a more complete molecular view of the anatomical structures of biological tissues.Keywords
Funding Information
- Deutsche Forschungsgemeinschaft (DFG Sp 314/13‐1, SFB 824 TP Z02, C4)
This publication has 48 references indexed in Scilit:
- Mass spectrometry imaging with high resolution in mass and spaceHistochemistry and Cell Biology, 2013
- Correlated imaging – a grand challenge in chemical analysisThe Analyst, 2013
- A New Safety Concern for Glaucoma Treatment Demonstrated by Mass Spectrometry Imaging of Benzalkonium Chloride Distribution in the Eye, an Experimental Study in RabbitsPLOS ONE, 2012
- High‐resolution matrix‐assisted laser desorption/ionization imaging of tryptic peptides from tissueRapid Communications in Mass Spectrometry, 2012
- Desorption Electrospray Ionization then MALDI Mass Spectrometry Imaging of Lipid and Protein Distributions in Single Tissue SectionsAnalytical Chemistry, 2011
- Lipid mapping of colonic mucosa by cluster TOF-SIMS imaging and multivariate analysis in cftr knockout miceJournal of Lipid Research, 2010
- A New Dynamic in Mass Spectral Imaging of Single Biological CellsAnalytical Chemistry, 2008
- C60 Secondary Ion Mass Spectrometry with a Hybrid-Quadrupole Orthogonal Time-of-Flight Mass SpectrometerAnalytical Chemistry, 2008
- Lipid mapping in human dystrophic muscle by cluster-time-of-flight secondary ion mass spectrometry imagingJournal of Lipid Research, 2008
- Impact of slow gold clusters on various solids: nonlinear effects in secondary ion emissionNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1991