Performance of Three Reflectance Calibration Methods for Airborne Hyperspectral Spectrometer Data
Open Access
Abstract
In this study, the performances and accuracies of three methods for converting airborne hyperspectral spectrometer data to reflectance factors were characterized and compared. The “reflectance mode (RM)” method, which calibrates a spectrometer against a white reference panel prior to mounting on an aircraft, resulted in spectral reflectance retrievals that were biased and distorted. The magnitudes of these bias errors and distortions varied significantly, depending on time of day and length of the flight campaign. The “linear-interpolation (LI)” method, which converts airborne spectrometer data by taking a ratio of linearly-interpolated reference values from the preflight and postflight reference panel readings, resulted in precise, but inaccurate reflectance retrievals. These reflectance spectra were not distorted, but were subject to bias errors of varying magnitudes dependent on the flight duration length. The “continuous panel (CP)” method uses a multi-band radiometer to obtain continuous measurements over a reference panel throughout the flight campaign, in order to adjust the magnitudes of the linear-interpolated reference values from the preflight and post-flight reference panel readings. Airborne hyperspectral reflectance retrievals obtained using this method were found to be the most accurate and reliable reflectance calibration method. The performances of the CP method in retrieving accurate reflectance factors were consistent throughout time of day and for various flight durations. Based on the dataset analyzed in this study, the uncertainty of the CP method has been estimated to be 0.0025 ± 0.0005 reflectance units for the wavelength regions not affected by atmospheric absorptions. The RM method can produce reasonable results only for a very short-term flight (e.g., < 15 minutes) conducted around a local solar noon. The flight duration should be kept shorter than 30 minutes for the LI method to produce results with reasonable accuracies. An important advantage of the CP method is that the method can be used for long-duration flight campaigns (e.g., 1-2 hours). Although this study focused on reflectance calibration of airborne spectrometer data, the methods evaluated in this study and the results obtained are directly applicable to ground spectrometer measurements.Keywords
This publication has 13 references indexed in Scilit:
- A Technique for Reflectance Calibration of Airborne Hyperspectral Spectrometer Data Using a Broad, Multiband Radiometer2008
- Assessing the seasonal dynamics of the Brazilian Cerrado vegetation through the use of spectral vegetation indicesInternational Journal of Remote Sensing, 2004
- Optical characterization of the Brazilian Savanna physiognomies for improved land cover monitoring of the cerrado biome: preliminary assessments from an airborne campaign over an LBA core siteJournal of Arid Environments, 2004
- Angular and seasonal variation of spectral surface reflectance ratios: implications for the remote sensing of aerosol over landIEEE Transactions on Geoscience and Remote Sensing, 2001
- Evaluation of simplified procedures for retrieval of land surface reflectance factors from satellite sensor outputRemote Sensing of Environment, 1992
- Biological Feedbacks in Global DesertificationScience, 1990
- Surface reflectance factor retrieval from thematic mapper dataRemote Sensing of Environment, 1989
- Evaluating evaporation from field crops using airborne radiometry and ground-based meteorological dataIrrigation Science, 1987
- Radiometric considerations in remote sensingProceedings of the IEEE, 1985
- Vegetational Changes on a Semidesert Grassland Range from 1858 to 1963Ecological Monographs, 1965