Biomechanical Behavior of Bioactive Material in Dental Implant: A Three-Dimensional Finite Element Analysis
Open Access
- 7 May 2020
- journal article
- research article
- Published by Wiley in The Scientific World Journal
- Vol. 2020, 1-9
Abstract
Dental implants are widely accepted for the rehabilitation of missing teeth due to their aesthetic compliance, functional ability, and great survival rate. The various components in implant design like thread design, thread angle, pitch, and material used for manufacturing play a critical role in its success. Understanding these influencing factors and implementing them properly in implant design can reduce cases of potential implant failure. Recently, finite element analysis (FEA) is being widely used in the field of health sciences to solve problems in designing medical devices. It provides valid and accurate assessment in the clinical and in vitro analysis. Hence, this study was conducted to evaluate the impact of thread design of the implant and 3 different bioactive materials, titanium alloy, graphene, and reduced graphene oxide (rGO) on stress, strain, and deformation in the implant system using FEA. In this study, the FEA model of the bones and the tissues are modeled as homogeneous, isotropic, and linearly elastic material with a titanium implant system with an assumption of it 100% osseointegrated into the bone. The titanium was functionalized with graphene and graphene oxide. A modeling software tool Catia® and Ansys Workbench® is used to perform the analysis and evaluate the von Mises stress distribution, strain, and deformation at the implant and implant-cortical bone interface. The results showed that the titanium implant with a surface coating of graphene oxide exhibited better mechanical behavior than graphene, with mean von Mises stress of 39.64 MPa in pitch 1, 23.65 MPa in pitch 2, and 37.23 MPa in pitch 3. It also revealed that functionalizing the titanium implant will help in reducing the stress at the implant system. Overall, the study emphasizes the use of FEA analysis methods in solving various biomechanical issues about medical and dental devices, which can further open up for invivo study and their practical uses.Keywords
This publication has 53 references indexed in Scilit:
- Influence of Micro Threads Alteration on Osseointegration and Primary Stability of Implants: An FEA and In Vivo Analysis in RabbitsClinical Implant Dentistry and Related Research, 2013
- Dental implants from functionally graded materialsJournal of Biomedical Materials Research Part A, 2013
- Preparation of functionalized graphene sheets by a low-temperature thermal exfoliation approach and their electrochemical supercapacitive behaviorsElectrochimica Acta, 2010
- The effect of thread pattern upon implant osseointegrationClinical Oral Implants Research, 2010
- The effect of thread design on stress distribution in a solid screw implant: a 3D finite element analysisClinical Oral Investigations, 2009
- Finite element analysis of the bone remodelling process considering bone condensing around osseointegrated dental implantsJournal of Biomechanics, 2006
- Characterization of functionally graded hydroxyapatite/titanium composite coatings plasma‐sprayed on Ti alloysJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2005
- Finite Element Analysis of an Osseointegrated Stepped Screw Dental ImplantJournal of Oral Implantology, 2004
- Comparative evaluation of the effect of diameter, length and number of implants supporting three-unit fixed partial prostheses on stress distribution in the boneJournal of Dentistry, 2002
- Stress relaxation function of bone and bone collagenJournal of Biomechanics, 1993