A fast and direct spectrophotometric method for the simultaneous determination of methyl paraben and hydroquinone in cosmetic products using successive projections algorithm
Authors:
- 11 June 2015
- journal article
- Published by Wiley in International Journal of Cosmetic Science
- Vol. 38 (1) , 25-34
Abstract
Synopsis: Objective: To develop a simple and efficient spectrophotometric technique combined with chemometrics for the simultaneous determination of methyl paraben (MP) and hydroquinone (HQ) in cosmetic products, and specifically, to: (i) evaluate the potential use of successive projections algorithm (SPA) to derivative spectrophotometric data in order to provide sufficient accuracy and model robustness and (ii) determine MP and HQ concentration in cosmetics without tedious pre‐treatments such as derivatization or extraction techniques which are time‐consuming and require hazardous solvents.Methods: The absorption spectra were measured in the wavelength range of 200–350 nm. Prior to performing chemometric models, the original and first‐derivative absorption spectra of binary mixtures were used as calibration matrices. Variable selected by successive projections algorithm was used to obtain multiple linear regression (MLR) models based on a small subset of wavelengths. The number of wavelengths and the starting vector were optimized, and the comparison of the root mean square error of calibration (RMSEC) and cross‐validation (RMSECV) was applied to select effective wavelengths with the least collinearity and redundancy. Principal component regression (PCR) and partial least squares (PLS) were also developed for comparison. The concentrations of the calibration matrix ranged from 0.1 to 20 μg mL−1 for MP, and from 0.1 to 25 μg mL−1 for HQ. The constructed models were tested on an external validation data set and finally cosmetic samples.Results: The results indicated that successive projections algorithm–multiple linear regression (SPA‐MLR), applied on the first‐derivative spectra, achieved the optimal performance for two compounds when compared with the full‐spectrum PCR and PLS. The root mean square error of prediction (RMSEP) was 0.083, 0.314 for MP and HQ, respectively. To verify the accuracy of the proposed method, a recovery study on real cosmetic samples was carried out with satisfactory results (84–112%).Conclusion: The proposed method, which is an environmentally friendly approach, using minimum amount of solvent, is a simple, fast and low‐cost analysis method that can provide high accuracy and robust models. The suggested method does not need any complex extraction procedure which is time‐consuming and requires hazardous solvents.Keywords
Funding Information
- University of Zanjan
This publication has 39 references indexed in Scilit:
- Dietary exposure to phenolic and methoxylated organohalogen contaminants in relation to their concentrations in breast milk and serum in JapanEnvironment International, 2014
- Determination of 19 Preservatives in Various Matrices by High-Performance Liquid ChromatographyAnalytical Letters, 2012
- Fast and sensitive high performance liquid chromatography analysis of cosmetic creams for hydroquinone, phenol and six preservativesJournal of Chromatography A, 2011
- LC-determination of five paraben preservatives in saliva and toothpaste samples using UV detection and a short monolithic columnJournal of Pharmaceutical and Biomedical Analysis, 2010
- Safety assessment of personal care products/cosmetics and their ingredientsToxicology and Applied Pharmacology, 2010
- Human health safety evaluation of cosmetics in the EU: A legally imposed challenge to scienceToxicology and Applied Pharmacology, 2010
- State of the Evidence: The Connection Between Breast Cancer and the EnvironmentInternational Journal of Occupational and Environmental Health, 2009
- High-performance liquid chromatographic assay of parabens in wash-off cosmetic products and foods using chemiluminescence detectionAnalytica Chimica Acta, 2005
- Concentrations of parabens in human breast tumoursJournal of Applied Toxicology, 2004
- Contents of methyl‐, ethyl‐, propyl‐, butyl‐ and benzylparaben in cosmetic productsContact Dermatitis, 1995