Incidence, predictors, and clinical outcomes of coronary obstruction following transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves: insights from the VIVID registry
Top Cited Papers
Open Access
- 14 August 2017
- journal article
- research article
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 39 (8) , 687-695
Abstract
There are limited data on coronary obstruction following transcatheter valve-in-valve (ViV) implantation inside failed aortic bioprostheses. The objectives of this study were to determine the incidence, predictors, and clinical outcomes of coronary obstruction in transcatheter ViV procedures. A total of 1612 aortic procedures from the Valve-in-Valve International Data (VIVID) Registry were evaluated. Data were subject to centralized blinded corelab computed tomography (CT) analysis in a subset of patients. The virtual transcatheter valve to coronary ostium distance (VTC) was determined. A total of 37 patients (2.3%) had clinically evident coronary obstruction. Baseline clinical characteristics in the coronary obstruction patients were similar to controls. Coronary obstruction was more common in stented bioprostheses with externally mounted leaflets or stentless bioprostheses than in stented with internally mounted leaflets bioprostheses (6.1% vs. 3.7% vs. 0.8%, respectively; P < 0.001). CT measurements were obtained in 20 (54%) and 90 (5.4%) of patients with and without coronary obstruction, respectively. VTC distance was shorter in coronary obstruction patients in relation to controls (3.24 ± 2.22 vs. 6.30 ± 2.34, respectively; P < 0.001). Using multivariable analysis, the use of a stentless or stented bioprosthesis with externally mounted leaflets [odds ratio (OR): 7.67; 95% confidence interval (CI): 3.14–18.7; P < 0.001] associated with coronary obstruction for the global population. In a second model with CT data, a shorter VTC distance predicted this complication (OR: 0.22 per 1 mm increase; 95% CI: 0.09–0.51; P < 0.001), with an optimal cut-off level of 4 mm (area under the curve: 0.943; P < 0.001). Coronary obstruction was associated with a high 30-day mortality (52.9% vs. 3.9% in the controls, respectively; P < 0.001). Coronary obstruction following aortic ViV procedures is a life-threatening complication that occurred more frequently in patients with prior stentless or stented bioprostheses with externally mounted leaflets and in those with a short VTC.Keywords
This publication has 22 references indexed in Scilit:
- Aortic Root Dimensions Among Patients With Severe Aortic Stenosis Undergoing Transcatheter Aortic Valve ReplacementJACC: Cardiovascular Interventions, 2013
- Updated Standardized Endpoint Definitions for Transcatheter Aortic Valve ImplantationJACC, 2012
- Guidelines on the management of valvular heart disease (version 2012)European Heart Journal, 2012
- Coronary obstruction following transcatheter aortic valve‐in‐valve implantation for failed surgical bioprosthesesCatheterization and Cardiovascular Interventions, 2011
- Multimodal Assessment of the Aortic Annulus DiameterJACC, 2010
- Recommendations for Evaluation of Prosthetic Valves With Echocardiography and Doppler UltrasoundJournal of the American Society of Echocardiography, 2009
- Aortic root morphology in patients undergoing percutaneous aortic valve replacement: Evidence of aortic root remodelingThe Journal of Thoracic and Cardiovascular Surgery, 2009
- Noninvasive Evaluation of the Aortic Root With Multislice Computed TomographyJACC: Cardiovascular Imaging, 2008
- Coronary flow obstruction in percutaneous aortic valve replacement. An in vitro studyEuropean Journal of Cardio-Thoracic Surgery, 2007
- Percutaneous Aortic Valve Implantation Retrograde From the Femoral ArteryCirculation, 2006