The Imperial Joint Line Congruency Measurement is a valuable tool in total knee arthroplasty
Open Access
- 10 September 2021
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (9) , e0257325
Abstract
Background: Preservation of joint line height is an important factor in post-operative function after Total Knee Arthroplasty (TKA). This is the first study investigating the reliability of the novel Imperial Joint Line Congruency Measurement (IJLCM) technique for the assessment of joint line height using plain radiographs.Methods: The reliability of two techniques used to measure joint line height on pre-operative and post-operative plain radiographs is presented. 120 patients that underwent TKA from 6 different international centres were included. Measurements were performed using each technique by two senior orthopaedic surgeons at two different timepoints (test-retest). Two undergraduate medical students performed joint line measurements using the most reproducible of the two techniques on 40 pre-operative and post-operative images to establish the reliability of the measurement technique.Results: The IJLCM demonstrated an average absolute difference of 1.83mm (CI 1.56–2.10mm) and excellent inter and intra-rater reliability between senior orthopaedic surgeons (>0.92 (CI 0.88–0.94) when measuring joint line height on plain radiographs. Overall Crohnbach’s alpha over 0.92 confirmed internal consistency. Measurements performed using the control technique as previously described by Figgie et al. had an average absolute difference of 5.75mm (5.17–6.32mm). Comparison of measurements by senior orthopaedic surgeons and medical students using the IJLCM technique with ANOVA and student’s t-test demonstrated acceptable agreement and inter-rater reliability of >0.92 (0.87–0.95).Conclusion: This study shows excellent accuracy, precision, and reliability of the novel IJLCM technique. Furthermore, excellent agreement between senior orthopaedic surgeons and medical students when using the IJLCM could be shown. The IJLCM technique is reliable for joint line assessment.Keywords
This publication has 18 references indexed in Scilit:
- Joint line changes in cruciate-retaining versus posterior-stabilized computer-navigated total knee arthroplastyArchives of orthopaedic and trauma surgery, 2013
- Joint line position correlates with function after primary total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2011
- The Influence of the Posterior Cruciate Ligament and Component Design on Joint Line Position After Primary Total Knee ArthroplastyThe Journal of Arthroplasty, 2009
- Joint line elevation in revision TKA leads to increased patellofemoral contact forcesJournal of Orthopaedic Research, 2009
- Clinical and Radiographic Analysis of Accurate Restoration of the Joint Line in Revision Total Knee ArthroplastyThe Journal of Arthroplasty, 2006
- Does total knee joint replacement with the soft tissue balancing surgical technique maintain the natural joint line?Archives of orthopaedic and trauma surgery, 2006
- Factors affecting range of flexion after total knee arthroplastyJournal of Orthopaedic Science, 2001
- Effect of tibial component position on patellar strain following total knee arthroplastyThe Journal of Arthroplasty, 1995
- Influence of prosthetic joint line position on knee kinematics and patellar positionThe Journal of Arthroplasty, 1991
- Recurrent Dislocation and the High-riding PatellaClinical Orthopaedics and Related Research, 1972