Quantitative prediction of contrast enhancement from test bolus data in cardiac MSCT
- 18 November 2006
- journal article
- cardiac
- Published by Springer Nature in European Radiology
- Vol. 17 (5) , 1310-1319
Abstract
The purpose of this study was to evaluate a new algorithm for the prediction of contrast enhancement from test bolus data in cardiac multislice spiral computed tomography (MSCT). An algorithm for the prediction of contrast enhancement using test bolus data was developed. A total of 30 consecutive patients (15 male, 69.5 ± 9.6 years) underwent cardiac MSCT (12 × 0.75 mm, 120 kV, 500 mAseff.) with a biphasic contrast material injection protocol. Contrast timing was derived from a standard 20 ml test bolus injection. Based on the test bolus time attenuation curves, expected enhancement values were computed for the ascending and descending aorta and the pulmonary trunk and compared with measured data from the cardiac CT scan. At the level of the test bolus measurement in the ascending aorta, the corresponding attenuation values were 309.4 ± 49.6 Hounsfield Units (HU) for the predicted and 285.6 ± 42.6 HU for the measured attenuation, respectively. The mean deviation between predicted and measured CT values was 32.8 ± 48.2 HU (upper and lower limits of agreement 101.4/−53.8 HU), indicating a slight systematic tendency for overestimation. For 80% of the patients the prediction error was less than 50 HU. Prediction of contrast enhancement in cardiac MSCT from test bolus data is feasible with a relatively small mean deviation; 80% of the predictions were within a range that might be acceptable for routine clinical application.Keywords
This publication has 27 references indexed in Scilit:
- Empirical cupping correction: A first‐order raw data precorrection for cone‐beam computed tomographyMedical Physics, 2006
- Contrast-enhanced coronary artery visualization by dual-source computed tomography—Initial experienceEuropean Journal of Radiology, 2006
- High-Resolution Spiral Computed Tomography Coronary Angiography in Patients Referred for Diagnostic Conventional Coronary AngiographyCirculation, 2005
- Diagnostic Accuracy of Noninvasive Coronary Angiography Using 64-Slice Spiral Computed TomographyJACC, 2005
- Quantification of Obstructive and Nonobstructive Coronary Lesions by 64-Slice Computed TomographyJACC, 2005
- Accuracy of MSCT coronary angiography with 64-slice technology: first experienceEuropean Heart Journal, 2005
- Optimal Contrast Application for Cardiac 4-Detector-Row Computed TomographyInvestigative Radiology, 2003
- A method for simultaneous correction of spectrum hardening artifacts in CT images containing both bone and iodineMedical Physics, 1997
- Determination of Scan Delay Time in Spiral CT-AngiographyJournal of Computer Assisted Tomography, 1995
- Indicator Transit Time Considered as a Gamma VariateCirculation Research, 1964