Carotid CTA: Radiation Exposure and Image Quality with the Use of Attenuation-Based, Automated Kilovolt Selection
Authors:
Open Access
- 1 August 2013
- journal article
- research article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 35 (2) , 237-241
Abstract
BACKGROUND AND PURPOSE: CTA is considered the imaging modality of choice in evaluating the supraaortic vessels in many institutions, but radiation exposure remains a matter of concern. The objective of the study was to evaluate a fully automated, attenuation-based kilovolt selection algorithm in carotid CTA in respect to radiation dose and image quality compared with a standard 120-kV protocol. MATERIALS AND METHODS: Ninety-eight patients were included: 53 examinations (patient age, 66 ± 12 years) were performed by use of automated adaption of tube potential (80–140 kV) on the basis of the attenuation profile of the scout scan (study group), and 45 examinations (patient age, 67 ± 11 years) were performed by use of a standard 120-kV protocol (control group). CT dose index volume and dose-length product were recorded from the examination protocol. Image quality was assessed by ROI measurements and calculations of SNR and contrast-to-noise ratio. Subjective image quality was evaluated by 2 observers with the use of a 4-point scale (3, excellent; 0, not diagnostic). RESULTS: Subjective image quality was rated as “excellent” or “good” in all examinations (study group, 2.8; control group, 2.8). The algorithm automatically selected 100 kV in 47% and 80 kV in 34%; 120 kV was retained in 19%. An elevation to 140 kV did not occur. Compared with the control group, overall CT dose index volume reduction was 33.7%; overall dose-length product reduction was 31.5%. In the low-kilovolt scans, image noise and mean attenuation of ROIs inside the carotid arteries were significantly higher than in 120-kV scans, resulting in a constant or increased (80-kV group) contrast-to-noise ratio. CONCLUSIONS: The attenuation-based, kilovolt selection algorithm enables a dose reduction of >30% in carotid artery CTA while maintaining contrast-to-noise ratio and subjective image quality at adequate levels.Keywords
This publication has 37 references indexed in Scilit:
- Attenuation-Based Automatic Kilovolt Selection in Abdominal Computed TomographyInvestigative Radiology, 2012
- CT angiography of intracranial arterial vessels: impact of tube voltage and contrast media concentration on image qualityActa Radiologica, 2012
- The Current Role of Carotid Duplex Ultrasonography in the Management of Carotid Atherosclerosis: Foundations and AdvancesInternational Journal of Vascular Medicine, 2012
- Automated Attenuation-Based Tube Potential Selection for Thoracoabdominal Computed Tomography AngiographyInvestigative Radiology, 2011
- Diagnostic accuracy of colour Doppler ultrasonography, CT angiography and blood-pool-enhanced MR angiography in assessing carotid stenosis: a comparative study with DSA in 170 patientsLa radiologia medica, 2011
- Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experienceThe International Journal of Cardiovascular Imaging, 2010
- Performance Assessment of Dynamic Spiral Scan Modes With Variable Pitch for Quantitative Perfusion Computed TomographyInvestigative Radiology, 2010
- The effect of angular and longitudinal tube current modulations on the estimation of organ and effective doses in x‐ray computed tomographyMedical Physics, 2009
- DNA Double-Strand Breaks and Their Repair in Blood Lymphocytes of Patients Undergoing Angiographic ProceduresInvestigative Radiology, 2009
- Contrast-Enhanced MR Angiography Is Not More Accurate Than Unenhanced 2D Time-of-Flight MR Angiography for Determining ≥70% Internal Carotid Artery StenosisAmerican Journal of Neuroradiology, 2009