Improved Standardization of Flow Cytometry Diagnostic Screening of Primary Immunodeficiency by Software-Based Automated Gating
Authors:
Open Access
- 2 November 2020
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Immunology
- Vol. 11
Abstract
Background: Multiparameter flow cytometry (FC) is essential in the diagnostic work-up and classification of primary immunodeficiency (PIDs). The EuroFlow PID Orientation tube (PIDOT) allows identification of all main lymphocyte subpopulations in blood. To standardize data analysis, tools for Automated Gating and Identification (AG&I) of the informative cell populations, were developed by EuroFlow. Here, we evaluated the contribution of these innovative AG&I tools to the standardization of FC in the diagnostic work-up of PID, by comparing AG&I against expert-based (EuroFlow-standardized) Manual Gating (MG) strategy, and its impact on the reproducibility and clinical interpretation of results. Methods: FC data files from 44 patients (13 CVID, 12 PID, 19 non-PID) and 26 healthy donor (HD) blood samples stained with PIDOT were analyzed in parallel by MG and AG&I, using Infinicyt™ software (Cytognos). For comparison, percentage differences in absolute cell counts/µL were calculated for each lymphocyte subpopulation. Data files showing differences >20% were checked for their potential clinical relevance, based on age-matched percentile (p5-p95) reference ranges. In parallel, intra- and inter-observer reproducibility of MG vs AG&I were evaluated in a subset of 12 samples. Results: The AG&I approach was able to identify the vast majority of lymphoid events (>99%), associated with a significantly higher intra- and inter-observer reproducibility compared to MG. For most HD (83%) and patient (68%) samples, a high degree of agreement (Conclusion: Altogether, our results indicate that replacement of MG by the AG&I module would be associated with a greater reproducibility and robustness of results in the diagnostic work-up of patients suspected of PID. However, expert revision of the results of AG&I of PIDOT data still remains necessary in samples with numerical alterations and aberrant B- and T-cell maturation and/or marker expression profiles.Keywords
This publication has 25 references indexed in Scilit:
- Next Generation Flow for highly sensitive and standardized detection of minimal residual disease in multiple myelomaLeukemia, 2017
- Standardized flow cytometry for highly sensitive MRD measurements in B-cell acute lymphoblastic leukemiaBlood, 2017
- Primary Immunodeficiency Diseases2017
- Primary immunodeficiencies worldwide: an updated overview from the Jeffrey Modell Centers Global NetworkImmunologic Research, 2016
- The end of gating? An introduction to automated analysis of high dimensional cytometry dataEuropean Journal of Immunology, 2015
- An Introduction to Automated Flow Cytometry Gating Tools and Their ImplementationFrontiers in Immunology, 2015
- Glucose Metabolism Regulates T Cell Activation, Differentiation, and FunctionsFrontiers in Immunology, 2015
- Overview of clinical flow cytometry data analysis: recent advances and future challengesTrends in Biotechnology, 2013
- EuroFlow standardization of flow cytometer instrument settings and immunophenotyping protocolsLeukemia, 2012
- Automated pattern-guided principal component analysis vs expert-based immunophenotypic classification of B-cell chronic lymphoproliferative disorders: a step forward in the standardization of clinical immunophenotypingLeukemia, 2010