Virtual Mass Feedback for Rendering Stiff Virtual Springs
Authors:
- 1 July 2019
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 211-216
Abstract
Rendering stiff virtual walls is of interest in the haptics domain. As one of the approaches, stiff springs can be rendered by adding virtual damping in an impedance controlled haptic interface. In this paper, we study the effect of incorporation of virtual mass on maximum renderable stiffness of a bilateral wall. The haptic interface is analyzed as a discrete time state-space system using exact discretization technique. Analytical stability boundary is obtained by solving for the roots of the characteristics polynomial. The main result of the paper shows that the maximum stiffness is rendered when the mass feedback is close to the mass of the device. For the devices with low inertia this means, at low frequencies, a high stiffness can be stably rendered with little compromise on the transparency of the system. Experiments performed on a single degree of freedom haptic interface validate the analytical results. The uncoupled stability of the interface is verified for the response of the device for initial displacement condition. The accuracy of displayed stiffness is validated when the user interacts with the wall. This further ensures the coupled stability of the device for the performed experiments. We show that the maximum stiffness achieved with virtual mass is about 2.5 times higher than that can be achieved with virtual damping.Keywords
This publication has 16 references indexed in Scilit:
- Effects of discretization on the K-width of series elastic actuators2017
- Transparency enhancement of haptic interface using model matching approach2016
- Stability and quantization-error analysis of haptic rendering of virtual stiffness and dampingThe International Journal of Robotics Research, 2015
- M-Width: Stability, noise characterization, and accuracy of rendering virtual massThe International Journal of Robotics Research, 2015
- Design and Evaluation of a Peaucellier-Lipkin Linkage Based Haptic Interface2014
- Inertia Compensation Control of a One-Degree-of-Freedom Exoskeleton for Lower-Limb Assistance: Initial ExperimentsIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2012
- Stability Boundary for Haptic Rendering: Influence of Damping and DelayJournal of Computing and Information Science in Engineering, 2009
- Stability Analysis of a 1 DOF Haptic Interface Using the Routh–Hurwitz CriterionIEEE Transactions on Control Systems Technology, 2004
- Passivity of a class of sampled-data systems: Application to haptic interfacesJournal of Robotic Systems, 1997
- Design and evaluation of a high-performance haptic interfaceRobotica, 1996