Abstract
This study proposes a method for stator fault detection of inverter‐fed induction machine in closed‐loop control. The sideband response of inverter switching harmonics in common‐mode voltage (CMV) is employed to detect the stator inter‐turn fault, thus no additional injected signal is necessary. However, the PWM nature harmonics introduce undesired CMV signals, depending on the inherent imbalance or resistance asymmetry. For this reason, the CMV amplitude is not suitable to indicate the fault directly. In this study, the behaviour of switching harmonic is analysed first, and then a simple but efficient stator fault model is demonstrated. To suppress the adverse interference from inverter, an inter‐turn fault indicator is proposed by utilising both of the switching sidebands. This method can obtain fault location and severity with low sensitivity to steady operating condition and stator imbalance. The experimental results validate the effectiveness of the proposed method.Keywords
This publication has 29 references indexed in Scilit:
- Online Turn Fault Detection of Interior Permanent-Magnet Machines Using the Pulsating-Type Voltage InjectionIEEE Transactions on Industry Applications, 2016
- Advances in Electrical Machine, Power Electronic, and Drive Condition Monitoring and Fault Detection: State of the ArtIEEE Transactions on Industrial Electronics, 2014
- New Expressions of Symmetrical Components of the Induction Motor Under Stator FaultsIEEE Transactions on Industrial Electronics, 2012
- A Survey of Condition Monitoring and Protection Methods for Medium-Voltage Induction MotorsIEEE Transactions on Industry Applications, 2010
- Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical MotorsIEEE Transactions on Industrial Electronics, 2010
- Fast Single-Turn Sensitive Stator Interturn Fault Detection of Induction Machines Based on Positive- and Negative-Sequence Third Harmonic Components of Line CurrentsIEEE Transactions on Industry Applications, 2010
- Advances in Diagnostic Techniques for Induction MachinesIEEE Transactions on Industrial Electronics, 2008
- A Survey on Testing and Monitoring Methods for Stator Insulation Systems of Low-Voltage Induction Machines Focusing on Turn Insulation ProblemsIEEE Transactions on Industrial Electronics, 2008
- A Survey of Methods for Detection of Stator-Related Faults in Induction MachinesIEEE Transactions on Industry Applications, 2007
- Online Diagnosis of Induction Motors Using MCSAIEEE Transactions on Industrial Electronics, 2006