Abstract
Human 3D Engineered Neural Tissue (ENT) made of neurons derived from human induced pluripotent stem cells (hiPSC) are among the most promising tools for the next decade in drug discovery and neurotoxicology. It represents a cheaper, faster and more ethical alternative to in vivo animal testing that will likely close the bridge between in vitro animal models and human clinical trials. MEA recordings of spontaneous activity in ENTs offer a non-invasive, real-time and long-term assessment of compounds' effects. However, the use of ENTs (diameter 0.5mm to 1mm) on MicroElectrode Arrays (MEA) involves a series of constraints, such as drastically limited diffusion of oxygen and nutrients due to the lack of vascularization. As a consequence, ENTs are extremely sensitive to experimental conditions and require adequately designed MEA devices that allow the maintenance of an air-liquid interface around ENTs during culture and recording. Past results using 3D glass tip-shaped electrode MEA devices (Heuschkel et al 2002) have demonstrated advantages in the use of 3D versus 2D electrode geometries when monitoring acute brain slices from rodents. In order to improve currently available polyimide-based 2D MEA devices used in combination with ENTs at our laboratory, novel 3D electrode arrays that present electrodes protruding from the porous polyimide substrate have been developed. The manufactured MEA devices are composed of 4 independent wells, where the bottom of each well is made of a porous polyimide membrane (thickness of 8µm) that integrates 8 platinum recording electrodes arranged on a 200µm grid and 2 large reference electrodes. Planar 2D electrodes do have the following characteristics: a circular shape, a diameter of 30µm, and are coated with black platinum material providing low impedance (20-30kΩ @ 1kHz). Based on the same electrode arrangement, the novel 3D electrodes have a square pyramidal or a square truncated pyramidal shape, which are the simplest shapes that can be achieve using microfabrication processes. Obtained electrode heights are 25µm and 35µm for pyramidal electrodes and 25µm for truncated pyramidal electrodes. Resulting platinum electrode impedance is in the range of 300-800kΩ @ 1kHz depending on shape and dimensions of the 3D electrodes. Similar to results from 3D tip-shaped glass electrode arrays, recordings of spontaneous activity from ENTs show that larger signal amplitudes can be recorded with the 3D pyramidal polyimide MEA devices. Furthermore, the recordings from 3D electrodes display a variety of more complex signal shapes (multiple waves) that are less present in planar electrode MEA devices, which suggests that the 3D electrodes configuration reduces the distance between the electrodes and the active cells and neurites within the tissue by slight penetration into the tissue. In conclusion, a novel stand-alone MEA device specifically designed for medium-throughput testing of human 3D engineered neural tissue based on 3D porous polyimide MEA devices has been built and characterized.