Microwave reflectometry: A high-resolution technique for measuring vibration of capacitive microresonators
Authors:
- 1 June 2013
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 2159547X,p. 566-569
Abstract
The paper proposes a novel technique for measuring the vibration of capacitive microelectromechanical resonators. Based on microwave reflectometry in the gigahertz range, the technique offers signal-to-noise ratio greater than 100 dB for the studied device and it rejects any parasitic crosstalk due to stray capacitances. Experiments demonstrate that amplitude resolution better than 10 fm/√Hz is achieved, which competes with standard optical interferometry. The technique is particularly appropriate for electrical characterization of MEMS devices but also for signal processing of resonant sensors when large-bandwidth, high signal-to-noise ratio and fully electrical detection is required.Keywords
This publication has 4 references indexed in Scilit:
- MEMS Ring Resonators for Laserless AFM With Sub-nanoNewton Force ResolutionJournal of Microelectromechanical Systems, 2012
- DNA origami imaging with 10.9 MHz AFM MEMS probes2012
- Laterally Driven Polysilicon Resonant MicrostructuresSensors and Actuators, 1989
- Integrated resonant-microbridge vapor sensor1984