Determining eosin as a groundwater migration tracer by capillary electrophoresis/laser‐induced fluorescence using a multiwavelength laser
- 16 July 2003
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 24 (14) , 2335-2339
Abstract
Measurements for determining of the path of groundwater migration remain an important tool in the overall assessment of environmental processes and transport of pollutants. This paper examines a multiwavelength laser for the determination of eosin, a groundwater tracer, using capillary electrophoresis/laser‐induced fluorescence (CE‐LIF) at excitation wavelength 514.5 nm. Eosin was one of four dyes used in a study of adjacent resource conservation and recovery act (RCRA) and Superfund sites (created by the comprehensive environmental response, compensation, and liability act) that routinely relied on spectrofluorimetry for determination as we have previously reported. However, the improved specificity of CE‐LIF is further illustrated in this work applied to the analysis of adsorbent pads placed in monitoring wells after dye injection and flushing from injection wells. The multiwavelength laser provided the capability to analyze for several dyes with one laser. The advantages/disadvantages of CE‐LIF versus spectrofluorimetry are discussed. Spectrofluorimetry is fast and sensitive and will likely continue to be the primary workhorse technique. CE‐LIF could provide confirmation when greater specificity is needed in a regulatory context.Keywords
This publication has 11 references indexed in Scilit:
- Investigation of capillary electrophoresis-laser induced fluorescence as a tool in the characterization of sewage effluent for fluorescent acids: Determination of salicylic acidElectrophoresis, 2002
- Recent advances in capillary electrophoresis and capillary electrochromatography of pollutantsElectrophoresis, 2001
- Capillary electrophoresis and electrochromatography of pesticides and metabolitesElectrophoresis, 2001
- Capillary electrophoresis/laser‐induced fluorescence detection of fluorescein as a groundwater migration tracerElectrophoresis, 1998
- Single-Molecule Detection in Capillary Electrophoresis: Molecular Shot Noise as a Fundamental Limit to Chemical AnalysisAnalytical Chemistry, 1996
- Wavelength-Resolved Fluorescence Detection in Capillary ElectrophoresisAnalytical Chemistry, 1995
- Electrophoretic behavior of aromatic-containing organic acids and the determination of selected compounds in water and soil by capillary electrophoresisJournal of Chromatography A, 1993
- A procedure for enriching and cleaning up Rhodamine B and rhodamine WT in natural waters, using a Sep-pak C18 cartridgeWater Research, 1984
- Use of Tracers to Confirm Ground‐Water Flow aGroundwater, 1978
- An evaluation of some fluorescent dyes for water tracingWater Resources Research, 1977