Assessment of indoor absorbed gamma dose rate from natural radionuclides in concrete by the method of build-up factors
Authors:
- V. ManiVMV. Mani
- D. NikezicDND. Nikezic
- D. KrsticDKD. Krstic
- G. ManiGMG. Mani
- 12 January 2014
- journal article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 162 (4) , 609-617
Abstract
The specific absorbed gamma dose rates, originating from natural radionuclides in concrete, were calculated at different positions of a detection point inside the standard room, as well as inside an example room. The specific absorbed dose rates corresponding to a wall with arbitrary dimensions and thickness were also evaluated, and appropriate fitting functions were developed, enabling dose rate calculation for most realistic rooms. In order to make calculation simpler, the expressions fitting the exposure build-up factors for whole (238)U and (232)Th radionuclide series and (40)K were derived in this work, as well as the specific absorbed dose rates from a point source in concrete. Calculated values of the specific absorbed dose rates at the centre point of the standard room for (238)U, (232)Th and (40)K are in the ranges of previously obtained data.Keywords
This publication has 18 references indexed in Scilit:
- Calculation of dose rate conversion factors for 238U, 232Th and 40K in concrete structures of various dimensions, with application to Nis, SerbiaRadiation Protection Dosimetry, 2012
- External exposure doses due to gamma emitting natural radionuclides in some Egyptian building materialsApplied Radiation and Isotopes, 2012
- CALCULATION OF INDOOR EFFECTIVE DOSE FACTORS IN ORNL PHANTOMS SERIES DUE TO NATURAL RADIOACTIVITY IN BUILDING MATERIALSHealth Physics, 2009
- Energy Absorption Buildup Factors and Energy ConservationJournal of Nuclear Science and Technology, 2009
- New model for dwelling dose calculation using Monte Carlo integrationRadiation Protection Dosimetry, 2009
- Development of Fitting Methods Using Geometric Progression Formulae of Gamma-ray Buildup FactorsJournal of Nuclear Science and Technology, 2006
- Annual effective dose due to natural radionuclides in building blocks in eight cities of Southwestern NigeriaRadiation Protection Dosimetry, 2005
- Evaluation of indoor gamma radiation dose in dwellingsRadiation Protection Dosimetry, 2004
- Development of New Gamma-Ray Buildup Factor and Application to Shielding CalculationsJournal of Nuclear Science and Technology, 1991
- Calculation of Exposure Rates from Gamma Sources in Walls of Dwelling RoomsHealth Physics, 1978