Verification of threshold activation detection (TAD) technique in prompt fission neutron detection using scintillators containing19F
- 1 September 2015
- journal article
- research article
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 10 (09) , T09005
Abstract
In the present study 5''× 3'' and 2''× 2'' EJ-313 liquid fluorocarbon as well as 2'' × 3'' BaF2 scintillators were exposed to neutrons from a 252Cf neutron source and a Sodern Genie 16GT deuterium-tritium (D+T) neutron generator. The scintillators responses to β− particles with maximum endpoint energy of 10.4 MeV from the n+19F reactions were studied. Response of a 5'' × 3'' BC-408 plastic scintillator was also studied as a reference. The β− particles are the products of interaction of fast neutrons with 19F which is a component of the EJ-313 and BaF2 scintillators. The method of fast neutron detection via fluorine activation is already known as Threshold Activation Detection (TAD) and was proposed for photofission prompt neutron detection from fissionable and Special Nuclear Materials (SNM) in the field of Homeland Security and Border Monitoring. Measurements of the number of counts between 6.0 and 10.5 MeV with a 252Cf source showed that the relative neutron detection efficiency ratio, defined as BaF2 / EJ−313−5'', is 32.0% ± 2.3% and 44.6% ± 3.4% for front-on and side-on orientation of the BaF2, respectively. Moreover, the 5'' EJ-313 and side-on oriented BaF2 were also exposed to neutrons from the D+T neutron generator, and the relative efficiency BaF2 / EJ−313−5'' was estimated to be 39.3%. Measurements of prompt photofission neutrons with the BaF2 detector by means of data acquisition after irradiation (out-of-beam) of nuclear material and between the beam pulses (beam-off) techniques were also conducted on the 9 MeV LINAC of the SAPHIR facility.Keywords
This publication has 23 references indexed in Scilit:
- Light yield nonproportionality of doped CeF3scintillatorsJournal of Instrumentation, 2014
- Electron response of some low-Z scintillators in wide energy rangeJournal of Instrumentation, 2012
- The investigation of fast neutron Threshold Activation Detectors (TAD)Journal of Instrumentation, 2012
- Neutron threshold activation detectors (TAD) for the detection of fissionsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2011
- Linac based photofission inspection system employing novel detection conceptsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2011
- Measurement of Compton edge position in low-Z scintillatorsRadiation Measurements, 2010
- TUKAN-an 8K pulse height analyzer and multi-channel scaler with a PCI or a USB interfaceIEEE Transactions on Nuclear Science, 2006
- Background identification and suppression for the measurement of (n,γ) reactions with the DANCE array at LANSCENuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2004
- Light yield and surface treatment of barium fluoride crystalsNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1991
- Barium fluoride — Inorganic scintillator for subnanosecond timingNuclear Instruments and Methods in Physics Research, 1983