Application of Ni-Ti Alloy connector for the treatment of comminuted coronal plane supracondylar-condylar femoral fractures: a retrospective review of 21 patients
Open Access
- 17 December 2013
- journal article
- case report
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 14 (1) , 355
Abstract
Background: Our preliminary retrospective study assessed outcomes after the use of Ni-Ti arched shape-memory connector (ASC) combined with partially threaded cancellous screws (PTCS) to repair coronal plane supracondylar-condylar femoral fractures. Methods: Twenty-one patients (16 men and 5 women) with a mean age of 34.1 years (range, 28 to 44 years) with coronal plane supracondylar and condylar fractures of the distal femur were included in this study. Each patient underwent open reduction and internal fixation using the ASC and PTCS. Active functional exercises with restricted weight bearing were initiated the first postoperative day. A gradual increase in weight bearing status and range of motion was permitted and subjects progressed to full weight bearing by 8 weeks. Surgical time, blood loss, postoperative knee range of motion, American Knee Society Scores (KSS), and postoperative complications were assessed. Results: The mean surgical time was 75 mins (range, 45 to 100 mins) and average blood loss was 105 ml (range, 35 to 130 ml). Mean follow-up was 65 months (range, 22 to 90 months). No subjects demonstrated evidence of osteonecrosis or arthritis at the final follow-up. The mean KSS was excellent (≥85) in 8 subjects, good (70-84) in 11 subjects, and fair (60-69) in 2 subjects. The mean active range of motion of knee flexion at final follow-up was 100 degrees (range, 85 to 110 degrees). Conclusions: ASC combined with PTCS can serve as an effective means for managing comminuted femoral fractures that extend from the condyle to the supracondylar region. However, further prospective comparative studies and biomechanical analyses are needed to evaluate long-term outcomes using these materials.Keywords
This publication has 35 references indexed in Scilit:
- Operative management of Hoffa fractures—A prospective review of 18 patientsInjury, 2011
- Understanding the Shape-Memory Alloys Used in OrthodonticsISRN Dentistry, 2011
- Lower-limb adaptation during squatting after isolated posterior cruciate ligament injuriesClinical Biomechanics, 2010
- Reverse LISS plating for intertrochanteric Hip Fractures in elderly patientsBMC Musculoskeletal Disorders, 2010
- Biomechanical study of posterior wall acetabular fracture fixation using acetabular tridimensional memory alloy-fixation systemClinical Biomechanics, 2010
- Application of a shape-memory alloy internal fixator for treatment of acetabular fractures with a follow-up of two to nine years in ChinaInternational Orthopaedics, 2009
- Shape memory Ni-Ti alloy swan-like bone connector for treatment of humeral shaft nonunionInternational Orthopaedics, 2009
- Fixation of Distal Femoral Fractures With the Less Invasive Stabilization System: A Minimally Invasive Treatment With Locked Fixed-Angle ScrewsJournal of Trauma: Injury, Infection & Critical Care, 2008
- Coronal Fractures of the Femoral CondyleJournal of Orthopaedic Trauma, 2004
- Long Term Results of Unicondylar Fractures of the FemurJournal of Orthopaedic Trauma, 1994