Fully Automatic Software for Retinal Thickness in Eyes With Diabetic Macular Edema From Images Acquired by Cirrus and Spectralis Systems
Open Access
- 1 November 2013
- journal article
- research article
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 54 (12) , 7595-7602
Abstract
Purpose.: To determine whether a novel automatic segmentation program, the Duke Optical Coherence Tomography Retinal Analysis Program (DOCTRAP), can be applied to spectral-domain optical coherence tomography (SD-OCT) images obtained from different commercially available SD-OCT in eyes with diabetic macular edema (DME). Methods.: A novel segmentation framework was used to segment the retina, inner retinal pigment epithelium, and Bruch's membrane on images from eyes with DME acquired by one of two SD-OCT systems, Spectralis or Cirrus high definition (HD)-OCT. Thickness data obtained by the DOCTRAP software were compared with those produced by Spectralis and Cirrus. Measurement agreement and its dependence were assessed using intraclass correlation (ICC). Results.: A total of 40 SD-OCT scans from 20 subjects for each machine were included in the analysis. Spectralis: the mean thickness in the 1-mm central area determined by DOCTRAP and Spectralis was 463.8 ± 107.5 μm and 467.0 ± 108.1 μm, respectively (ICC, 0.999). There was also a high level agreement in surrounding areas (out to 3 mm). Cirrus: the mean thickness in the 1-mm central area was 440.8 ± 183.4 μm and 442.7 ± 182.4 μm by DOCTRAP and Cirrus, respectively (ICC, 0.999). The thickness agreement in surrounding areas (out to 3 mm) was more variable due to Cirrus segmentation errors in one subject (ICC, 0.734–0.999). After manual correction of the errors, there was a high level of thickness agreement in surrounding areas (ICC, 0.997–1.000). Conclusions.: The DOCTRAP may be useful to compare retinal thicknesses in eyes with DME across OCT platforms.Keywords
This publication has 13 references indexed in Scilit:
- Comparison of Macular Thickness in Diabetic Macular Edema Using Spectral-Domain Optical Coherence Tomography and Time-Domain Optical Coherence TomographyJournal of Ophthalmology, 2012
- Validated Automatic Segmentation of AMD Pathology Including Drusen and Geographic Atrophy in SD-OCT ImagesInvestigative Ophthalmology & Visual Science, 2012
- Spectral- and time-domain optical coherence tomography measurements of macular thickness in normal eyes and in eyes with diabetic macular edemaEye, 2011
- Quality and Reproducibility of Retinal Thickness Measurements in Two Spectral-Domain Optical Coherence Tomography MachinesInvestigative Ophthalmology & Visual Science, 2011
- Comparison of manually corrected retinal thickness measurements from multiple spectral-domain optical coherence tomography instrumentsBritish Journal of Ophthalmology, 2011
- RETINAL THICKNESS AND VOLUME MEASUREMENTS IN DIABETIC MACULAR EDEMARetina, 2011
- Automatic segmentation of seven retinal layers in SDOCT images congruent with expert manual segmentationOptics Express, 2010
- Evaluation of Artifacts Associated with Macular Spectral-Domain Optical Coherence TomographyOphthalmology, 2010
- Randomized Trial Evaluating Ranibizumab Plus Prompt or Deferred Laser or Triamcinolone Plus Prompt Laser for Diabetic Macular EdemaOphthalmology, 2010
- Burden of illness of diabetic macular edema: literature reviewCurrent Medical Research and Opinion, 2010