Modern principles of the radiation protection from sources of ionizing radiation in medicine. Part 1: Trends, structure of x-ray diagnostics and doses from medical exposure
Open Access
- 27 March 2019
- journal article
- Published by SPRI of Radiation Hygiene Prof. PV Ramzaev in Radiatsionnaya Gygiena = Radiation Hygiene
- Vol. 12 (1) , 6-24
Abstract
Implementation of modern highly informative methods of X-ray diagnostics (computed tomography, interventional examinations, nuclear medicine), associated with the increase of doses to the public and patients, requires the development and improvement of the existing system of the radiation protection from medical exposure. Despite the prevalence of the traditional imaging modalities in the structure of X-ray diagnostics in the Russian Federation (radiography and fluorography compose up to 95% out of 280 mln. X-ray examinations performed in 2017), the major contribution into the collective dose from medical exposure is due to the computed tomography (50,5%). Comparison of the structure of X-ray diagnostics in the Russian Federation with European Union indicates the absence of fluorography examinations and significantly (up to a factor of 5) higher contribution of computed tomography in European countries. An average collective dose from medical exposure in European countries is composed of 80% of computed tomography and of 10% of nuclear medicine; a mean effective dose per X-ray examination are higher up to a factor of 3 compared to Russia. The analysis of the trends of the development of the X-ray diagnostic in the Russian Federation allows predicting a further increase of the number of computer tomography, interventional and nuclear medicine examinations as well as an increase of the collective dose from medical exposure up to a factor of two in the next decade. This will be associated with changes in the structure of the X-ray diagnostics and an increase of the mean effective doses from X-ray examinations.Keywords
This publication has 35 references indexed in Scilit:
- Influence of intraoperative conventional fluoroscopy versus cone beam CT on long-term clinical outcome in isolated displaced talar fracturesJournal of Orthopaedic Surgery and Research, 2019
- T and N Staging of Gastric Cancer Using Dual-Source Computed TomographyGastroenterology Research and Practice, 2018
- SURVEY OF IMAGING TECHNOLOGY AND PATIENT DOSE RECORDING PRACTICE IN DEVELOPING COUNTRIESRadiation Protection Dosimetry, 2018
- Patient doses from medical examinations in Russia: 2009–2015Journal of Radiological Protection, 2017
- Patient dose monitoring and the use of diagnostic reference levels for the optimization of protection in medical imaging: current status and challenges worldwideJournal of Medical Imaging, 2017
- Children, medical radiation and the environment: An important dialogueEnvironmental Research, 2017
- Dual-Energy CT: New Horizon in Medical ImagingKorean Journal of Radiology, 2017
- LEVELS OF PATIENTS EXPOSURE AND A POTENTIAL FOR OPTIMIZATION OF THE PET DIAGNOSTICS IN THE RUSSIAN FEDERATIONRadiatsionnaya Gygiena = Radiation Hygiene, 2017
- PATIENT DOSES IN COMPUTED TOMOGRAPHY EXAMINATIONS IN TWO REGIONS OF THE RUSSIAN FEDERATIONRadiation Protection Dosimetry, 2016
- Cone beam CT in dental practiceBritish Dental Journal, 2009